254 not been installed. [Tr eatment] Please res elect the device which is curr ently installed. E906041 “There is no instal led head” [Cause] You could not spec ify a head since there is no head available. [Treatm ent] P…
253
E691013 “The data version for the common data of flush memory is
abnormal”
[Cause] The version of the common data that is saved in the flush memory and the
version of the application are clashing with each other.
• The application was versioned up.
[Treatment]
E691014 “The data length for the common data of flush memory is abnormal”
[Cause] The data length of the common data that is saved in the flush memory is irregular.
The common data of flush memory is broken.
• Flush memory is broken.
[Treatment] • Please re-start the application.
• Please re-install or version up the application.
• If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E691015 “The data kind for the common data is abnormal”
[Cause] Data type parameter is invalid.
[Treatment] • Please re-start the application.
• Please re-install or version up the application.
• If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E906001 “Memory allocation error”
[Cause] The working space can not be saved.
[Treatment] Please increase some more memory available to save the working space.
E906002 “Shared memory open error”
[Cause] The shared memory could not be open.
[Treatment] Please shut down the your machine and re-start it.
E906011 “Measurement result exceeds limit value. Check the MS parameter”
[Cause] An assemblage position offset of a measured head exceeded the limit value. The
limit is: -9.9999 through 9.9999
[Treatment] System error
Please check the MS parameter.
E906021 “Return to home has not yet been completed”
[Cause] The axis has not yet been returned to home.
[Treatment] Please perform the Return to home with ORIGIN switch.
E906022, “Servo is in the free state”
[Cause] The axis could not move since the servo is not locked.
[Treatment] Please lock the servo with S-FREE switch.
E906031 “Selected device is not install. Please reselect other device on HOD”
[Cause] You could not go into the teaching mode since the device selected by HOD has
254
not been installed.
[Treatment] Please reselect the device which is currently installed.
E906041 “There is no installed head”
[Cause] You could not specify a head since there is no head available.
[Treatment] Please set to “use” in the Use unit setting in Machine Setup.
E906042 “There is no installed VCS”
[Cause] You could not specify VCS since no VCS has been installed or there is no VCS
available.
[Treatment] Your request is not available on the machine that do not have VCS. If your
machine has VCS, please set the VCS to “Use” in the Use unit setting in Machine
Setup.
E906043 “%s is disable. Selected unit can not measure”
[Cause] The selected head is set to “not use” in the Use unit setting in Machine Setup.
[Treatment] Please set the head to “use” in the Use unit setting in Machine Setup
E906051 “No nozzle 501 or 502 are present in ATC. Add either nozzle using
ATC setup”
[Cause] 501 nozzle and 502 nozzle have not been allocated to ATC. Please allocated a
nozzle using the ATC nozzle allocation in Machine Setup.
[Treatment] Please assign 501 nozzle or 502 nozzle to ATC in the ATC nozzle allocation in
Machine Setup.
E906052 “No nozzle 508 or 507 are present in ATC. Add either nozzle using
ATC setup”
[Cause] 508 nozzle and 507 nozzle have not been allocated to ATC. Please allocated a
nozzle using the ATC nozzle allocation in Machine Setup.
[Treatment] Please assign 507 nozzle or 508 nozzle to ATC in the ATC nozzle allocation in
Machine Setup.
E906061 “Mark on calibration jig for laser alignment has not been
acknowledged. Check the position of jig”
[Cause] The mark on the Calibration jig for laser alignment could not be recognized. The
position at where the Calibration jig has been set may be wrong or something is
wrong with VCS.
[Treatment] Please check the jig position and see if the jig is set to be able to see the first
mark and second mark illuminations of the Calibration block from the two holes
on the jig. If the jig position is correct, then something may be wrong with VCS.
E906062 “Mark on calibration jig for laser alignment has not been
acknowledged”
[Cause] The mark on the Calibration jig for laser alignment could not be recognized. The
position at where the Calibration jig has been installed may be wrong or
something is wrong with the vision unit.
[Treatment] Please check the position of the Calibration jig for laser alignment, which is
installed on the Calibration block. If the position is correct, then something might
be wrong with the vision unit.
255
E906071 “Calibration jig for laser alignment has not been picked up. Check
that jig is placed on calibration jig”
[Cause] Failed to pick up the Calibration jig for laser alignment. An Out-of-component
error occurred in the Laser recognition of the Calibration jig for laser alignment.
[Treatment] Please check and see if the Calibration jig for laser alignment is placed on the
Calibration block.
E906072 “Calibration jig for laser alignment has not been picked up. Check
that jig is placed on jig station”
[Cause] Failed to pick up the Calibration jig for laser alignment. An out-of-component error
occurred in the Laser recognition of the Calibration jig for laser alignment.
[Treatment] Please check and see if the Calibration jig for laser alignment is placed on the
Calibration station.
E906073 “Error between the locations of jig placed and calibration block
exceeds limit value. Check the MS parameter”
[Cause] After measuring the assemblage position offset of a head, the Calibration jig for
laser alignment was placed on the center of the Calibration block.. The placement
position deviated from the Calibration block by more than 1.
[Treatment] System error
Please check the MS parameter.
E906074 “Position of calibration jig for laser alignment has irregularities.
Check the position of jig”
[Cause] The position of the Calibration jig for laser alignment on the Calibration block is
irregular.
The center of the recognized mark is more than 0.5mm far from the center of the
Calibration block..
[Treatment] Please place the jig to make the recognized mark ‘circular’.
E906075 “Calibration jig for VCS has not been picked up. Check that jig is
placed on jig station”
[Cause] Failed to pick up the Calibration jig for VCS. An out-of-component error occurred
in the Laser recognition of the Calibration jig for VCS.
[Treatment] Please check and see if the Calibration jig for laser alignment is placed on the
Calibration station.
E906101 “Error has occurred when detecting height of measuring plane of
laser code:%ld”
[Cause] An error occurred when measuring the height by laser.
?: Error code
2: The shadow does not get clear when lifting Z axis up.
3: There is not shadow when lowering Z axis down.
4: After detecting a shadow once, Z axis was lifted up but the
shadow does not get clear.
-1: A communication error occurred.
-2: An axis error occurred.
[Treatment] Something may be wrong with the Laser alignment. Please check the Laser