− Measurement operation
① The system measures the nozzle rotation center with laser.
(When the left 1 head is selected)
The machine has finished measurement operation.
To repeat the measurement operation, select the <Exec.> button.
When you select the <Exec.> button, the previous screen reappears.
To measure another head, select the head in the “Select Head” combo box.
When you change the selected head in the combo box, the initial screen
appears.
To quit this operation, select the <OK> button.

10 − 11
10.5 Head Offset
When you select the [Set-up group] command on the menu bar, then the [Head
offset] command on the displayed menu, the following the “Head offset” dialog box
appears on the screen.
Figure 10.5.1 Head offset screen
− Select Head
Using this combo box, select the head to be set.
The heads which are not checked on the “Device enable” menu invoked from the
Machine Setup menu (that is, checked as “Not used”) cannot be selected.
When you press the Alt key and the down arrow key at the same time, the
following list appears on the screen.
(Assembling angle
already set)
(Assembling angle
measured)

10 − 12
(1) Setting items
No. Item Description
1 Assembling position of head Mounting position of each head viewed from the OCC
2 Assembling angle of LA Mounting angle of the laser alignment onto the main unit (relative to
the main unit) (° )
(2) How to set
− For the head selected in the “Select Head” combo box, follow the instructions
displayed on the dialog box to set the selected head.
− When you click the <OK> button, your setting becomes valid (but not be
saved at this point).
− When you click the <CANCEL> button, your setting becomes invalid.
− How to operate
Follow the displayed instructions to obtain the appropriate value automatically.
The machine sets up the head selected with the combo box.
Click the <Exec.> button.
When you click the <Exec.> button, the machine starts measurement.
− Measurement operation
① Attach the No. 508 nozzle onto the selected head.
An error occurs if no nozzle is set for the ATC. In this case, assign the
nozzle on the “ATC nozzle setup” menu invoked from the Machine Setup
menu.
② Move the jig from the jig station to the calibration block if there is no jig on
the calibration block.
An error occurs if the jig cannot be picked up. In this case, remount the
jig.