56 E290000 “The origin point return is non-compl etion. Pl ease execute the teaching after t he origin point ret urns” [Cause] Hom e retur ning has not been com plete yet. [Treatm ent] Pleas e press ORIGIN button to perf…

100%1 / 1361
55
E249010 “Servo is in the free state. The bank mark recognition is aborted”
[Cause] The axis could not move since the servo was not locked.
[Treatment] Please lock the servo using S-FREE switch.
Q249051 “Feeder bank has descended. Do you want to lift the feeder bank up
and continue the bank mark recognition?
[Cause] The feeder bank had been descended when you tried to perform the Bank mark
recognition.
[Treatment] YES” button will continue the Bank mark recognition process.
NO” button will completely abort the Bank mark recognition process.
I249070 “Set online for MTS”
[Cause] Failed to draw the MTS tray out since the MTS was not online.
[Treatment] Please make MTS online.
I249071 “Please close the door of MTS”
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.
56
E290000 “The origin point return is non-completion. Please execute the
teaching after the origin point returns”
[Cause] Home returning has not been complete yet.
[Treatment] Please press ORIGIN button to perform the Home returning, then try the teaching
again.
E290001 “The OCC device is set in unused by the setup. The teaching in the
OCC device cannot be done”
[Cause] OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If OCC is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290002 “The bad mark reader device is set in unused by the setup. The
teaching in the bad mark reader device cannot be done”
[Cause] The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment] If the Bad mark reader device is available, please set it to “use” in the Use unit in
Setup. If not, this procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. The teaching in the
HMS device cannot be done”
[Cause] The HMS device is set to “not use” in the Use unit in Setup.
[Treatment] If the HMS device is available, please set it to “use” in the Use unit in Setup. If not,
this procedure cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching
with a left device. Please use a right device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the right
feeder bank to the machine by using a device on the left side.
[Treatment] Please use a device on the right side when teaching a feeder pickup coordinate
on the right feeder bank to the machine.
E290005 “The pick up point in the left feeder bank cannot be the teaching
with a right device. Please use a left device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the left
feeder bank to the machine by using a device on the right side.
[Treatment] Please use a device on the left side when teaching a feeder pickup coordinate on
the left feeder bank to the machine.
E290006 “The memory access error occurred”
[Cause] Failed to write the data in or to read the data from the shared memory.
[Treatment] Please reboot the machine. If the error occurs even after rebooting, please
contact our technical service dept. for information.
57
E290007 “The Head device is set in unused by the setup”
[cause] The specified head is set to “not use” in the Use unit in Setup.
[Treatment] If the specified head is available, please set it to “use” in the Use unit in Setup. If
not, this procedure cannot be executed.
E290008 “HW error. Execution is aborted”
[Cause] A requested action to an axis or other hardware got an error. There may be a
possibility of alarm occurrence, servo free, Emergency STOP, etc.
[Treatment] Please try Servo Free unlocking, Home returning, etc.
Q290500 “It is not possible to move to specified position with this device.
Please push ‘No’ when you discontinue ‘Yes’ when the teaching is
started from the current position”
[Cause] You can not move to the previously set coordinates with the device selected by
HOD. You are asked if to resume the teaching from the current position.
[Treatment] If you want to continue the process, press “Yes”. If not, press “No”.
Q290501 “The teaching operation is executed. Please confirm safety. Please
push ‘No’ when you discontinue ‘Yes’ when executing this”
[Cause] You are asked if to perform the safety check since this operation takes axis
traveling.
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290502 “The position cannot be corrected. Please push ‘No’ when you
discontinue ‘Yes’ when correction is not considered and teaching is
executed”
[Cause] You need to correct the coordinates in order to teach the coordinates to the
machine accurately, but the Mark recognition that is necessary for the coordinate
correction failed for some reason. You are asked if to continue the teaching
although the accurate teaching cannot be expected if you continue the process..
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290503 “The mark has already been registered. Do you overwrite?”
[Cause] There is a mark data left, which was registered before. You are asked if to
overwrite the data.
[Treatment] If you want to overwrite the data, press ‘Yes’. If not, press ‘No’.