KE2010.Instruction Manual.Ver.2.01,Rev.08.pdf - 第1142页

59 between the convey or width and the board size in Y direction. [Treatm ent] Please adjust the dif fer ence between the conveyor width and the board siz e in Y direction with a hand knob, then tr y again. E291011 “Cann…

100%1 / 1361
58
E291000 “Conveyor already operated, it is not possible to operation”
[Cause] The conveyor has already been in operation.
[Treatment] Please wait for a while and try again.
E291001 “The origin point return is non-completion. Please operate again
after completing the origin point return”
[Cause] Home returning has not been complete yet.
[Treatment] Please press the ORIGIN button to perform the Home returning, and try again.
E291002 “The axis cannot be moved to escape point. Execution is aborted”
[Cause] Failed to move the axis to the escape point.
[Treatment] Please check and see if the axis works properly with Manual control.
E291003 “The conveyor cannot be moved. Execution is aborted”
[Cause] The conveyor did not work for some reason.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291004 “The conveyor became a time-out. Execution is aborted”
[Cause] PWB conveying had a time-out error.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291005 “The axis cannot be moved. Execution is aborted”
[Cause] The axis could not move for some reason.
[Treatment] Please check and see if the axis works properly with Manual control.
E291006 “The BOC mark data is not set. Operation is aborted”
[Cause] BOC mark was not set in the Board data or the Board data is incomplete.
[Treatment] Please set and complete the board data.
E291007 “The OCC device is set in unused by the setup”
[Cause] The OCC device is set to “not use” in Setup.
[Treatment] If the device is available, set it to “use” in Setup. If not, this operation cannot be
executed.
E291008 “Value is mistake”
[Cause] The value is wrong when you hit the Enter key to define it.
[Treatment] Please check the entered value.
E291009 “Value out of range”
[Cause] The value when you hit the Enter key to define it exceeded the input range.
[Treatment] Please enter a value which is within the input range.
E291010 “Conveyor margin out of range. It is not possible to operation”
[Cause] Failed to take the value in as a margin since there is a too much difference
59
between the conveyor width and the board size in Y direction.
[Treatment] Please adjust the difference between the conveyor width and the board size in Y
direction with a hand knob, then try again.
E291011 “Cannot move conveyor”
[Cause] This error occurs when the conveyor width cannot be adjusted for some reason.
There is a possibility that an obstruction is being detected by a sensor on the
conveyor.
[Treatment] Please make sure that there is no obstruction to be detected by sensors between
the current position and the destination.
E291012 “The BOC mark recognition error [Circuit : %d / %d point]”
[Cause] VCS could not recognize the BOC mark(s).
?:
Circuit number
??:
The Xth BOC mark.
[Treatment] There is a possibility that the BOC mark(s) could not be taught to the machine
properly.
E291013 “The area sensor was detected. Execution is aborted”
[Cause] The process got forcibly aborted since the area sensor detected something.
[Treatment] Please remove the factor that was detected by the sensor.
E291014 “Emergency stopped. Execution is aborted”
[Cause] The process got forcibly aborted since the Emergency STOP occurred.
[Treatment.] Please remove the cause of the Emergency STOP.
E291015 “PWB exist in the entry side center buffer. Please execute retry
after ejection”
[Cause] PWB loading did not succeed since a PWB is staying on the inlet side of the
buffer.
[Treatment] Please take the PWB off the inlet side of the buffer.
E291016 “PWB exist in the exit side center buffer. Please execute retry after
ejection”
[Cause] PWB loading did not succeed since a PWB is staying on the outlet side of the
buffer.
[Treatment] Please take the PWB off the outlet side of the buffer.
E291017 “There is no completed pickup data”
[Cause] The process could not be executed since there is no complete data.
[Treatment] Please input and complete the pickup data.
60
E291018 “Input string is mistake”
[Cause] Character(s) was wrong when you hit the Enter key to define the caracter(s).
[Treatment] Please re-enter characters.
E291019 “Range is mistake”
[Cause] The value exceeded the input range when you hit the Enter key to define the
value.
[Treatment] Please enter a value which is within the input value.
E291020 “Please check the feeder to trace”
[Cause] No feeders to trace are selected.
[Treatment] Please select a feeder to trace.
E291021 “There is no completed placement data”
[Cause] This process could not be executed since there is no complete placement data.
[Treatment] Please input and complete the placement data.
E291022 “Because the one PWB is not clamped, cannot execute the BOC
alignment”
[Cause] Any PWBs are clamped on the conveyor buffer. If there is no PWB, BOC mark
recognition is not available.
[Treatment] Please load PWB(s) to BOC align.
E291023 “The automatic conveyor width adjustment is set in unused by the
setup”
[Cause] Auto. PWB Width Alignment Control is set to “not use” in Setup.
[Treatment] If Auto. PWB Width Alignment Control is available, please set it to “use” in the
Setup. If not, this operation cannot be executed.
E291024 “The BOC mark data send error [ID : &d]”
[Cause] BOC Mark data could not be sent to VCS.
? : BOC mark ID
[Treatment] Please re-teach the Mark data to the machine.
E291025 “Servo off, it is not possible to operation”
[Cause] Servo is in the free state.
[Treatment] Please perform the Home returning.
Q291500 “The BOC mark recognition error. Please push ‘No’ when
discontinuing. ‘Yes’ when continuing”
[Cause] The BOC mark(s) could not be recognized by VCS.
[Treatment] There is a possibility that the BOC mark(s) could not be taught to the machine
properly.