E650243 “PWB Conveying Error : PWB conveying error of the center station
on the Entrance side. The process is forcibly terminated. Please
remove on the conveying route”
[Cause] This error occurs if the C-OUT sensor on the center station on the Entrance side
got OFF then ON again, but it does not get OFF even if a certain amount of time
has passed since it got ON again when conveying a PWB on the center station
on the Entrance side to the center station on the Exit side.
[Treatment] 1 The PWB was on the position where it is detected by C-OUT sensor on the
center station on the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 The PWB was NOT on the position where it is detected by C-OUT sensor on
the center station on the Entrance side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being
conveyed, there is a possibility that the sensor is detecting something else.
Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor on the center station on the Entrance side in the
‘Status’ frame.
The sensitivity of C-OUT sensor may be too high. Please adjust it, using
the volume control knob attached to the sensor.
If the treatment1 does not work, there is a possibility that the C-OUT
sensor is broken, It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, that wiring got cut off, or
that sensor itself is broken. Please examine the wiring and the connector.
If any of them are broken, you need to replace them with new ones.
If the treatment2 does not work, a PCB is broken or the wiring between
the PCBs is bad.
E650244 “PWB Conveying Error : PWB conveying time out error of the center
station on the Entrance side. The process is forcibly terminated.
Please remove on the conveying route”
[Cause] This error occurred because the STOP sensor on the center station on the
Entrance side did not get ON even though a certain amount of time has passed
since the WAIT sensor on the Input buffer got OFF when conveying a PWB on
the Input buffer to the center station on the Entrance side. Usually, this error
occurs when a PWB can not go through the INPUT buffer for some reason.
[Treatment] 1 The PWB was on the position where it is NOT detected by WAIT sensor or
STOP sensor on the center station on the Entrance side when the error
occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust
the conveyor width.
The PWB you are trying to convey does not match the specifications
of your machine. The following cases do not match your machine.
216
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 If the belt was moving for a while after the PWB touched the stopper on the
center station on the Entrance side when the error occurred.
The STOP sensor on the center station on the Entrance side is not detecting
the PWB. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor in the ‘Status’ frame.
The sensitivity of the STOP sensor may be too low. Please re-adjust the
sensitivity of the sensor, using the volume control knob attached to the
sensor.
If the treatment1 does not work, there is a possibility that the STOP
sensor is broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector part is broken, that wiring got cut
off, or that sensor itself is broken. Please examine the wiring and the
connector. If any of them are broken, you need to replace them with the
new ones.
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.
E650252 “PWB conveying error of the center station on the Exit side. The
process is forcibly terminated. Please remove on the conveying
route”
[Cause] This error occurs if the STOP sensor on the center station on the Exit side got
OFF then ON again, but it does not get OFF even if a certain amount of time has
passed since it got ON again when conveying a PWB on the center station on the
Exit side to the Output buffer.
[Treatment] 1 The PWB was on the position where it is detected by STOP sensor on the
center station on the Exit side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 The PWB was NOT on the position where it is detected by STOP sensor on
the center station on the Exit side when the error occurred.
If the STOP sensor does not get OFF when a PWB is properly being
conveyed, there is a possibility the sensor is detecting something
else.@Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor in the ‘Status’ frame.
The sensitivity of the STOP sensor may be too high. Please re-adjust the
sensitivity of the sensor, using the volume control knob attached to the
sensor.
If the treatment1 does not work, there is a possibility that the STOP
sensor is broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector part is broken, that wiring got cut
off, or that sensor itself is broken. Please examine the wiring and the
connector. If any of them are broken, you need to replace them with the
new ones.
217
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.
E650253 “PWB Conveying Error : PWB conveying error of the center station
on the Exit side. The process is forcibly terminated. Please remove
on the conveying route”
[Cause] This error occurs if the C-OUT sensor on the center station on the Exit side got
OFF then ON again, but it does not get OFF even if a certain amount of time has
passed since it got ON again when conveying a PWB on the center station on the
Exit side to the Output buffer.
[Treatment] 1 The PWB was on the position where it is detected by C-OUT sensor on the
center station on the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 The PWB was NOT on the position where it is detected by C-OUT sensor on
the center station on the Entrance side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being
conveyed, there is a possibility that the sensor is detecting something else.
Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor on the center station on the Entrance side in the
‘Status’ frame.
The sensitivity of C-OUT sensor may be too high. Please adjust it, using
the volume control knob attached to the sensor.
If the treatment1 does not work, there is a possibility that the C-OUT
sensor is broken, It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, that wiring got cut off, or
that sensor itself is broken. Please examine the wiring and the connector.
If any of them are broken, you need to replace them with new ones.
If the treatment2 does not work, a PCB is broken or the wiring between
the PCBs is bad.
E650254 “PWB Conveying Error : PWB conveying time out error of the center
station on the Exit side. The process is forcibly terminated. Please
remove on the conveying route”
[Cause] This error occurred because the STOP sensor on the center station on the Exit
side did not get ON even though a certain amount of time has passed since the
C-OUT sensor on the center station on the Entrance side got OFF when
conveying a PWB on the center station on the Entrance side to the center station
on the Exit side. Usually, this error occurs when a PWB can not go through
conveyor for some reason.
[Treatment] 1 If the PWB is on the position where it is NOT detected by C-OUT sensor on
the Entrance side station and STOP sensor on the Exit side station when the
error occurred.
The PWB can not move for it got caught on the conveyor for some reason.