KE2010.Instruction Manual.Ver.2.01,Rev.08.pdf - 第578页

7 − 41 (2) How to set ① Select of delay time Use the radio butt on to change t he method f or set ting the sensor delay time. − STD: Sets t he delay time common t o all sensors. − Option: Sets t he delay time of each sen…

100%1 / 1361
7 40
7.2.2.12 PWB conveyor
A screen appears as shown in Figure 7.2.2.12.1 “PWB conveyor setting dialog box”
when [PWB conveyor] is selected from the [Setting Group] menu.
Figure 7.2.2.12.1 PWB conveyor setting dialog box
When you click the corresponding tab, you can specify the PWB conveyor or
Support table.
7.2.2.12.1 PWB conveyor
When you select the [PWB conveyor] tab, the “PWB conveyor” dialog box shown
in Figure 7.2.2.12.1 appears on the screen. This dialog box appears also as the
initial screen displayed when you click the [PWB conveyor] command on the
“Setting Group” menu.
(1) Setting items
No. Item Description
1 Select of delay time Sets the method for setting the delay time of the sensor.
2 Units of delay Sets the unit used for the delay time of the sensor(s) specified
on the “PWB conveyor” tab.
3 STD Sets the delay time of all sensors.
4 Option Sets the delay time of an independent sensor.
5 STOP sensor off as Re-clamp Sets the time while the STOP sensor keeps being set to OFF
until the machine detects the OFF status of the STOP sensor
when a board is clamped again.
6 Ready In delay time Set the Ready In signal delay time.
7 41
(2) How to set
Select of delay time
Use the radio button to change the method for setting the sensor delay
time.
STD: Sets the delay time common to all sensors.
Option: Sets the delay time of each sensor.
Units of delay
Use the radio button to select the unit for setting delay time.
When you select “time”, the value you entered as the delay time is
handled in the unit of ms.
When you select “length”, the value you entered as the delay time is
handled as the “delay distance” in the unit of mm.
Note: When you change the setting of this “Units of delay” item, the setting
of the item 3 “sensor delay time” is cleared.
sensor delay time
Set the sensor delay time in each input field as follows:
a. When you select “STD” in the “Select of delay time” column, set the
time for validating that all sensor are set to OFF.
b. When you select “Option” in the “Select of delay time” column, set the
continuous time for validating that each sensor is set to OFF.
c. In the “STOP sensor off as Re-clamp” field, set the continuous OFF
time to be passed until the system detects the OFF status of the
STOP sensor when a board is clamped again.
Enter a value in the range shown below when you select “STD” or
“Option” (default: 0):
a. “time” is selected as “Units of delay”
0 to 2500 ms (when MSP is set to 400 mm/s)
0 to 3300 ms (when MSP is set to 300 mm/s)
b. “length” is selected as “Units of delay”
0 to 1000.00 mm
Set a value in the range shown below to the “STOP sensor off as
Re-clamp” field:
a. “time” is selected as “Units of delay”
0 to 5000 ms
b. “length” is selected as “Units of delay”
0 to 200.00 mm
Ready In delay time
0 to 300 (default: 0)
The unit is fixed to second.
7 42
7.2.2.12.2 Support Table
When you click the “Support Table” tab, the “Support Table” setting dialog box
appears as shown in Figure 7.2.2.12.2.
Figure 7.2.2.12.2 “Support Table” setting dialog box
(1) Setting items
No. Item Description
1 Default back height Sets the PWB position lower limit on the support table.
2 Down Acceleration Sets the acceleration of the support table.
3 Support Table Overstroke Sets how much the support table should be pushed in.
(2) How to set
Default back height
Specify the value in the range from 5 to 40.
The unit is fixed to mm.
Down Acceleration
With using the radio button, set one of three steps; Low, Middle, and
High (default: High).
Support Table Overstroke
Specify the value in the range from 0.00 to 5.00.