173 E610044 “Head tr aveling coordinates are w i thin the head i nterference range(STOP)” [Cause] T he lef t and right heads can not m ove at high s peed since they interfere each other when they travel to the spec ified…
172
E610042 “A shadow is detected while nozzle detection after returning
nozzles”
[Cause] A nozzle was detected at a position where normal nozzles are not supposed to be
detected in the installation status checking which is performed after the nozzle
returning. There is a possibility that the nozzle could not be returned right or the
window of the laser sensor is dirty.
[Treatment] 1. If the nozzle was returned properly
There is a possibility that the window of the laser sensor is dirty. Please clean
the window of the sensor. You can check the dirt of the window with the
following procedures. Select [Manual Control] from the menu bar, and then
select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned laser
sensor in ‘Control’ unit, and then select ‘Image displaying’ from ‘Control Item’
frame. By enabling ON, an image data will be shown.
2. If the nozzle was not returned properly.
Please take the nozzle off the head part and set it on ATC. The following
causes are possible for why the nozzle could not be returned correctly.
①
There is an abnormal nozzle. Please examine if there is any obstructions
on the installation part on the head, or if it is damaged or deformed
②
Something is wrong with the movement of the ATC slide plate. In this
case, the following cases can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its
minimum limit. Please loosen the speed controller of the slide plate
driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong.
There is a possibility that the sensor gets ON before the slide plate
fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being
opened/closed. Please examine if there is anything caught in near
the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct.
Please examine if the air pipe is properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the
connector part of the slide plate plays too much. Please examine if
the nut is tightened up enough.
③
The ATC coordinates or the nozzle change height is not correct. If you
change the coordinates or the height, please select [Setup(S)] [MS
parameter] and follow the Maintenance manual. For MS parameter, it is
limited that who can change the parameter by the user level setting.
E610043 “Head traveling coordinates are within the head interference
range(SLOW)”
[Cause] The left and right heads can not move at high speed since they interfere each
other when they travel to the specified ATC position simultaneously. Some
program versions in the machine may be clashing with each other.
[Treatment] • Please turn off the power supply of your machine and reboot it.
• If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
• If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.
173
E610044 “Head traveling coordinates are within the head interference
range(STOP)”
[Cause] The left and right heads can not move at high speed since they interfere each
other when they travel to the specified ATC position simultaneously. Some
program versions in the machine may be clashing with each other.
[Treatment] • Please turn off the power supply of your machine and reboot it.
• If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
• If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.
E610045 “ATC(L) slide plate can not be shut down”
[Cause] ATC slide plate has to be closed when trying to change nozzles but it was open.
The process of closing the slide plate yet the plate did not get closed. This error is
likely to happen when the lock valve of the solenoid valve, which drives the slide
plate remains closed. The following causes are also possible.
①
The air is not being supplied properly.
②
The slide plate that slides left and right to open and close the plate in the ATC
unit does not work properly.
③
The sensor which detects the position of the slide plate is not tuned well or
broken.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C )]
[Other(O)] [ATC Control(A)]. Set ‘Control Unit’ to ‘light ATC’, and select ‘Slide
plate Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate.
Please perform one of the treatments below according to the result you get.
1. Slide plate works properly.
1.1 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too
much toward its minimum limit. Please loosen the controller.
1.2 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame does not get
ON/OFF.
①
There is a possibility that the Slide plate OFF sensor was adjusted to
out of the Cylinder’s movable range. Please re-adjust the sensor to
where it gets ON/OFF.
②
If the treatment1 does not work, there is a possibility that the slide
plate OFF sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.
③
If the treatment2 does not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Slide plate does not work.
①
There is a possibility that the lock valve of the solenoid valve, that drives
the slide plate, is closed. Please make sure that the lock valve of the
solenoid valve is opened all the way.
②
There is a possibility that a nozzle is not installed in the ATC correctly and
that prevent the slide plate from sliding properly. Please see if nozzles are
correctly installed in the ATC.
③
There is a possibility that a component or implement got caught in the
sliding part of the slide plate and that prevents the slide plate from sliding
properly. Please see if there is anything on the slide plate.
④
There is a possibility that the air supplying pipes to the slide plate driving
cylinder have a problem. It could be that the speed controller is fully
174
tightened up, that the air pipe came off the cylinder, or a wrong air pipe is
connected to the cylinder. Please see the air pipes and make sure that
correct pipes are connected.
⑤
There is a possibility that the connecting part between the shaft of the
slide plate driving cylinder and the slide plate has a problem. It could be
that the nut attached to the tip of the shaft fell off, that the shaft got
chipped or broken, or that the plate got chipped or broken. You need to
have the damaged part repaired or replace it with a new one.
⑥
There is a possibility that the slide plate driving cylinder is broken. Please
stop the air supplying on the machine and see if the slide plate works fine
manually. If the plate does not work smoothly, you need to replace it with
a new one.
⑦
There is a possibility that the slide plate driving solenoid valve is broken. It
could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that the wiring got cut off, or the solenoid
valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
⑧
If the treatments mentioned above do not work, a PCB is broken or the
wiring between the PCBs is bad.
E610046 “ATC(R) slide plate can not be shut down”
[Cause] ATC slide plate has to be closed when trying to change nozzles but it was open.
The process of closing the slide plate yet the plate did not get closed. This error is
likely to happen when the lock valve of the solenoid valve, which drives the slide
plate remains closed. The following causes are also possible.
①
The air is not being supplied properly.
②
The slide plate that slides left and right to open and close the plate in the ATC
unit does not work properly.
③
The sensor which detects the position of the slide plate is not tuned well or
broken.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C )]
[Other(O)] [ATC Control(A)]. Set ‘Control Unit’ to ‘right ATC’, and select ‘Slide
plate Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate.
Please perform one of the treatments below according to the result you get.
1. Slide plate works properly.
1.1 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too
much toward its minimum limit. Please loosen the controller.
1.2 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame does not get
ON/OFF.
①
There is a possibility that the Slide plate OFF sensor was adjusted to
out of the Cylinder’s movable range. Please re-adjust the sensor to
where it gets ON/OFF.
②
If the treatment1 does not work, there is a possibility that the slide
plate OFF sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.