193 E630052 “ViLi b Entry:Error Execute Undefined Command” [Cause] You tried to exec ute an undefined vision c om m and. Some pr ogram vers ions are clas hing with each other. [Treatm ent] Please re-ins tall or version u…

100%1 / 1361
192
E630001 “ViLib Entry : Failed in initializing.
[Cause] You tried to get several vision device drivers started at one time.
More than one application are running.
[Treatment] Please re-start the application.
E630002 “ViLib Entry : Un-initilizing error occurred”
[Cause] You tried to use a vision device driver without initializing it.
More than one application are running.
[Treatment] Please re-start the application.
E630003 “ViLib Thread:Driver Failed to get Thread starated”
[Cause] Failed to initialize a vision device driver internally.
Device manager did not get started properly.
[Treatment] Please re-boot your machine.
E630010 “There is no empty space in the Vision Resource Semaphore”
[Cause] A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment] Please re-boot your machine.
E630011 “ViLib Thread: Failed in registration of bass interrupting”
[Cause] A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment] Please re-boot your machine.
E630012 “ViLib Thread: Failed to open the serial port.”
[Cause] COM port does not return any response.
Another application is using COM port.
[Treatment] Please re-start the application.
E630050 “ViLib Entry: IPC Send Error(Entry->Thread) occurred”
[Cause] Failed in IPC transmission to the vision device driver.
The vision device driver is HOLT.
[Treatment] Please re-boot your machine.
E630051 “ViLib Entry: IPC Receive Error(Entry<-Thread) occurred”
[Cause] Failed in IPC reception from the vision device driver.
The vision device driver is HOLT.
[Treatment] Please re-boot your machine.
193
E630052 “ViLib Entry:Error Execute Undefined Command”
[Cause] You tried to execute an undefined vision command.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
E630053 “ViLib Thread: Undefined ViOS event is requested”
[Cause] You tried to execute an undefined vision command.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
E630073 “Vision Data: Ball patter has not been set yet”
[Cause] There is no ball patter data in the vision data.
[Treatment] Please examine the production program.
Please re-load the production program.
E630074 “Camera scale has not been set yet”
[Cause] There are some items that have not been set yet in the Camera scaling in MS
Parameter.
[Treatment] Please examine the Camera scaling in MS Parameter.
E630075 “The window frame does not fit in the screen”
[Cause] The component outer shape window frame does not fit in the screen if it is rotated
to the tracing posture.
[Treatment] The component is too large to trace.
E630081 “There is not valid mark within the detecting window
[Cause] The light is not ON.
There is no mark.
[Treatment] Please examine if the light gets on properly.
Please change the coordinates to where a mark exists or move the mark
detecting frame.
E630100 “Vision System: The parameter value is illegal”
[Cause] You tried to send an illegal data to VCS.
[Treatment] Please examine the parameter.
E630101 “Vision System: parameter count is wrong”
[Cause] The format of the command interface between the VCS and your machine is not
correct.
Some program versions are clashing with each other
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
E630102 “Vision System: You tried to register an undefined component or
mark”
[Cause] The format of the command interface between the VCS and your machine is not
194
correct.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
E630103 “Vision System: Component ID number is invalid”
[Cause] An invalid component ID number is sent.
[Treatment] Please examine the vision data in the production program.
Please re-load the production program.
E630104 “Vision System: Undefined command was issued”
[Cause] The format of the command interface between the VCS and your machine is not
correct.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
E630105 “Vision System: Recognition conditions are not enough”
[Cause] The vision data in the production program is broken.
The format of the command interface between the VCS and your machine is not
correct.
Some program versions are clashing with each other.
[Treatment] Please examine the vision data in the production program.
Please re-load the production program.
Please re-install or version up the application.
Please re-boot your machine.
E630106 “Vision System: There is not enough storage of the user defined
template”
[Cause] VCS does not have enough memory(Restorable error)
VCS does not have enough flash memory(Non-restorable error)
An error occurred in the hardware of VCS(Non-restorable error)
[Treatment] Please re-boot your machine.
Please change IMGCPUs.
E630107 “Vision System: You are ran out of the resources for the general
vision component data”
[Cause] Some settings of the general vision data in the production program data are
wrong.
A production program with old(new) format was read in.
VCS does not have enough memory(Restorable error)
Some program versions are clashing with each other.
[Treatment] Please examine the vision data in the production program.
Please see the completion status of the production program.
Please re-load the production program.
Please re-start the application.
Please re-install or version up the application.
Please re-boot your machine.
E630108 “Vision System: The component is not supported as General Vision
component”
[Cause] The vision data in the production program data is broken.
Some settings of the general vision data in the production program data are
wrong.
A production program with old(new) format was read in.