107 E600017 “Cannot operat e because of the feeder f loat sensor's detect ion.” [Cause] Indicates that the f eeder float s ensor detects som ething. [Treatm ent] Eliminate the c ause to which the f eeder float s ens…

100%1 / 1361
106
[Treatment]
Turn off the power, then turn on the power again.
Install the machine software again if the problem occurred after installing the software for
updating, etc.
If the error remains after the above processes, the board in the machine causes the problem.
Replace the board.
E600011 “Invalid unit”
[Cause]
Process for an invalid unit is tried.
[Treatment]
Turn off the power, then turn on the power again.
If the error remains after the restart, there is the possibility that the system file is broken.
Please take a note of the error number and contact our technical service dept. for information.
E600012 “Failed to return to the origin.”
[Cause]
Abnormality detected during returning to the origin.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error remains after the restart, there is the possibility that the axis becomes wrong.
Please take a note of the error number and contact our technical service dept. for information.
E600013 “Axis Driver: Servo power is OFF.”
[Cause]
The servo power is turned OFF.
The possible cause is; electrical restrictions, pressing of the emergency stop switch, detection
by the area sensor, or the power OFF state (of the safety type machine).
[Treatment]
Remove the cause and return the axes to the home position again.
E600014 “Axis Driver: Driver Alarm.”
[Cause]
A servo driver alarm is detected.
Possible cause is; poor contact or disconnection of the encoder cable, or an overload generated
by hitting an obstruction.
The alarm may also be caused if the emergency stop switch was pressed.
[Treatment]
Remove the cause and return the axes to the home position again.
E600015 “Axis Driver: Amp disabled.
[Cause]
The servo lock is released.
Mechanical or electrical load fluctuations may have generated a servo error.
A driver alarm or pressing of the emergency stop switch can also release the servo lock.
[Treatment]
Remove the cause and return the axes to the home position again.
E600016 “Axis Driver: Position of Z axis is low.”
[Cause]
The XY axis cannot move because the position of the Z axis is lower than the XY axis movable
range.
To move the XY axis, the unused heads must be elevated up to the position where the home
sensor can be turned ON.
[Treatment]
Turn the servo OFF and move any unused heads up to the height where the home sensor can
be turned ON.
107
E600017 “Cannot operate because of the feeder float sensor's detection.”
[Cause]
Indicates that the feeder float sensor detects something.
[Treatment]
Eliminate the cause to which the feeder float sensor is reacting.
E600018 “Cannot operate because of the board sensor's detection.”
[Cause]
Indicates that the board sensor detects something.
[Treatment]
Eliminate the cause to which the board sensor react is reacting.
E600020 “Failed to set the gain.”
[Cause]
Indicates that the system failed to set the gain parameters.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, take a note of the error number and contact our
technical service dept. for information.
E600021 “Axis Driver: Failed set LA encoder.”
[Cause]
An internal error occurred in the system.
The laser control board may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E600030 “Axis Driver: XMP error.”
[Cause]
An internal error occurred in the system.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E600031 “Axis Driver: Status error.”
[Cause]
The axis move was blocked during or at the start of the operation.
An initialization error, servo error or alarm may have been generated for the axis.
This error can also be displayed against errors for other axes.
Or, the XMP board may have failed.
[Treatment]
Press the emergency stop switch, and then return the axes to the home position again.
If the error persists, exit the system and contact our service engineer or the agency.
E600032 “Failed to start the axis operation.
[Cause]
Failed to start the axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E600033 “Failed to stop the axis operation.
[Cause]
Failed to stop the axis operation. There is the possibility of abnormal status in the XMP board.
108
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E600036 “Axis Driver: The velocity error exceeded the limit. (Check the
power supply for the possibilities of low power supply voltage.)”
[Cause]
An error occurred in the servo system.
Fluctuations in the driving power may have prevented the proper operation of the system.
[Treatment]
Check the conditions of the machine power source.
E600040 “Out of the movable range.”
[Cause]
The destination coordinates of the axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate within the movable range.
E601001 “Axis Driver: Failed servo power on.”
[Cause]
Could not turn ON the servo power.
The possible cause is; detection by the limit sensor or area sensor, pressing of the emergency
stop switch, or the power OFF state (of the safety type machine).
Also there may be wrong or poor electrical connections.
[Treatment]
Remove the cause and return the axes to the home position.
E601010 “Axis Driver: Failed amp enable. (XY)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601011 “Axis Driver: Failed amp enable. (YC)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601012 “Axis Driver: Failed amp enable. (ZT1)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601013 “Axis Driver: Failed amp enable. (ZT2)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.