73 meas urem ent range (- 40m m through +40m m ) [Treatm ent] Please check and s ee if the m easur ing position (X Y coordinates) of HMS is correct or not. E316301 “MTC pow er off” [Cause] T he power supply of MTC is off…
72
E316051 “Z axis limit has been exceeded”
[Cause] Z axis coordinate exceeded its limit. The axis can not move any further.
[Treatment] Please move the axis within the limitation.
E316101 “Error has occurred when setting laser parameters code:%ld”
[Cause] An abnormal matter happened when setting the Laser parameter.
?: Error code.
-1: A communication error occurred.
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316102 “Error has occurred during laser measurement(ONCE) code:%ld”
[Cause] An error occurred during the measurement(ONCE) by laser.
?: Error code.
-1 : A communication error.
Other : Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316103 “Error has occurred during laser measurement(SWEEP) code:%ld”
[Cause] An error occurred during the measurement(SWEEP) by laser.
?: Error code
-1: A communication error occurred.
-2: An axis error occurred
Other: Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316104 “Error has occurred during the nozzle presence check code:%ld"
[Cause] An error occurred during the measurement(ONCE) by laser.
?: Error code.
-1 : A communication error.
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316105 “Error has occurred during the image data obtain. code:%ld"
[Cause] An error occurred while getting the Image data by laser.
?: Error code
-1: A communication error occurred.
Other: Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316106 “Error has occurred during the edge check data learning.
code:%ld"
[Cause] An error occurred while getting the Edge check by laser.
?: Error code.
-1: A communication error occurred.
Other: Please reference [Status list] in [Laser Control] in Manual Control
[Treatment] Please reference [Status list] in [Laser Control] in Manual Control.
E316107 “Data has not been learned”
[Cause] Z axis coordinate by HMS could not be learned since it was out of the
73
measurement range (-40mm through +40mm)
[Treatment] Please check and see if the measuring position (XY coordinates) of HMS is
correct or not.
E316301 “MTC power off”
[Cause] The power supply of MTC is off.
[Treatment] Please turn on the power supply of MTC, and make it online.
E316302 “MTC offline”
[Cause] MTC is not online
[Treatment] Please make MTS online.
E316303 “MTC is in the supply state”
[Cause] MTC can not be controlled since it is in the Supply (component change) state.
[Treatment] Please make MTC a normal status.
E316401 “MTS power off”
[Cause] Failed to draw the MTS tray out since the MTS was not ON.
[Treatment] Please turn on the power supply of MTS.
E316402 “MTS offline”
[Cause] Failed to draw the MTS tray out since the MTS was not online.
[Treatment] Please make MTS online.
E316403 “MTS cannot move because of cover opening”
[Cause] Failed to draw the MTS tray out since the cover of the machine was open.
[Treatment] Please close the cover.
E316404 “The door of MTS opens”
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.
E316405 “There is no specified stacker with the tray steps number”
[Cause] Failed to draw the MTS tray out since there was no stacker which has the
specified number of trays.
[Treatment] Please set the stacker with specified number of trays.
E316501 “Error has occurred on axis code:%ld”
[Cause] An error occurred while an axis was traveling.
[Treatment]
E316502 “The initialization error of transportation occurred. Return to home
is interrupted. Error code:%ld”
[Cause] The initialization error of transportation occurred..
74
[Treatment]
E316503 “The PWB was detected in the transportation road”
[Cause] A PWB was detected on the conveyor.
[Treatment] “OK” will abort the process.
Q317001 “Exit manual control. Reset I/O?”
[Cause] This message appears when you choose to exit the Manual control. You are
asked if to set each I/O in the safety direction
[Treatment] “YES” button will sets I/O in the safety direction. “NO” button will discontinue to
exit the Manual control.
Q317011 “Return to home has not yet been completed. Return to home?”
[Cause] The axis has not yet been returned to home. You are asked if you want to
perform the Home returning.
[Treatment] “YES” button will return the axis to home, and continue the process. “NO” button
will not return the axis to home, and continue the process.
Q317021 “Cannot return component. Trash component?”
[Cause] A component was detected in the Component presence checking that is
performed when returning nozzle to ATC. The component can not be returned
since its pick position is unknown. You are asked if the component can be
disposed.
[Treatment] “YES” button will dispose the component at a disposal position. “NO” button will
move the head to the waiting position for nozzle removal, and request for a
manual component removal.
Q317031 “Do you interrupt process? ”
[Cause] STOP switch was pressed. You are asked if to abort the process.
[Treatment] “YES” button will abort the process. “NO” button will resume the process.
Q317041 “Is the tray of MTS stored?”
[Cause] “Exit MTS control screen” was chosen with MTS tray was drawn out.
[Treatment] “YES” will store the tray into MTS and exit the screen. “NO” will exit the screen
with MTS tray is drawn out of MTS.
I318001 “Remove the component from %s”
[Cause] The nozzle could not be returned to ATC since something, such as a component,
was on the nozzle.