4 – 140 Data ty pe Item Error conditions If the “Sequential and Mix Mode” is selected at the menu item “2030 Mode Specification” of the “2000 O ption” tab, “Use permanent nozzle setup from M SL Setup” is selected at the …

4 – 139
Data type Item Error conditions
The system cannot handle a bulk feeder type (BF25RS,
BF25CS, BF28RS or BF28CS).
*1
Bulk feeder type (BF25RS,
BF25CS, BF28RS, BF28CS)
There is no available bulk feeder (BF25RS, BF25CS,
BF28RS, BF28CS) when “Auto” is selected in Pick data
on a component, which is to use a bulk feeder.
*1
If an SOT direction-checking table cannot be used in the
placement data of an SOT component whose direction is
checked.
Placement of an SOT
component whose direction is
checked
(2000 series only)
– An IC recovery belt is not installed although the setting
item “Compo Reject to” of a component is set to “Trash
conveyor” and “Auto” is selected as a station in Pick data.
– An IC recovery belt is not installed although the setting
item “Compo Reject to” of a component to be picked up is
set to “Trash conveyor”.
Component Discarding
– The tray feeder (see Note) that is associated with the
component discarding destination is not installed although
the setting item “Compo Reject to” of a component to be
picked up is set to “Tray restore”, and “Auto” is selected as
a station in Pick data.
– The tray feeder (see Note) associated with the component
discarding destination is not installed although the setting
item “Compo Reject to” of a component to be picked up is
set to “Tray restore”.
– A station is set to an MTC when the setting item “Compo
Reject to” of a component is set to “Tray restore” and the
setting item “Shuttle” is set to “Mecha”.
Note: Tray feeders associated with the setting “Tray restore”
are as follows:
– MTC: TR6S, TR6D and TR4S
– MTS: TR5S and TR5D
– Tray holder: all types of tray holders
– DTS
Pick data
Overlapped with a DTS
If the area occupied by a specified feeder is overlapped with
that by a DTS.

4 – 140
Data type Item Error conditions
If the “Sequential and Mix Mode” is selected at the menu item
“2030 Mode Specification” of the “2000 Option” tab, “Use
permanent nozzle setup from MSL Setup” is selected at the
menu item “Nozzle” of the “Assignments” tab of the
“Optimization” menu, the menu item “SPLY” (supply) is all
entered to the pick data on the same component on the Pick
data screen that is associated with Component data, and a
nozzle specified on the Component data screen does not
exist on both of the stations.
Note that if a nozzle is located at either of both stations when
Pick data is set to both stations, the system will not handle
this situation as an error.
Pick data Nozzle (for a KE-2030)
If the “Sequential and Mix Mode” is selected at the menu item
“2030 Mode Specification” of the “2000 Option” tab, “Auto
arrange empty nozzle positions” is selected at the menu item
“Nozzle” of the “Assignments” tab of the “Optimization” menu,
the menu item “SPLY” (supply) is all entered to the pick data
on the same component on the Pick data screen that is
associated with Component data, and a nozzle specified on
the Component data screen does not exist on both of the
stations.
Note that if a nozzle is located at either of both stations when
Pick data is set to both stations, the system will not handle
this situation as an error.

4 – 141
(3-4) Coherence check items: error conditions
Data type Item Error conditions
Line The line cannot handle Vision data. *1
Placement of vision
components (over 0.4 mm)
(Lead components)
The standard VCS or optional VCS (37.5 mm, 27 mm or
18 mm) is not set in Placement data of vision
components whose size is 0.4 mm or larger.
*1
Placement of vision
components (0.3 <= Pitch < 0.4
mm) (Lead components)
The optional VCS (37.5 mm, 27 mm or 18 mm) is not
set in Placement data of vision components whose pitch
is 0.3 mm or wider, but narrower than 0.4 mm.
*1
Placement of vision
components (0.2 <= Pitch < 0.3
mm) (Lead components)
The optional VCS (27 mm or 18 mm) is not set in
Placement data of vision components whose pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (0.135 <= Pitch <
0.2 mm) (Lead components)
The optional 18 mm VCS is not set in Placement data of
vision components whose pitch is 0.135 mm or wider,
but narrower than 0.2 mm.
*1
Placement of general vision
components (15 < the smallest
pitch <= 22 mm) (Lead
components)
The standard VCS is not set in Placement data of
general vision components whose minimum pitch is
wider than 15 mm, but 22 mm or narrower.
*1
Placement of general vision
components (11 < the smallest
pitch <=15 mm) (Lead
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Placement of general vision
components (6.5 < the smallest
pitch <= 11 mm) (Lead
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of general vision
components whose minimum pitch is wider than 6.5
mm, but 11 mm or narrower.
*1
Placement of general vision
components (0.5 <= the
smallest pitch <=6.5 mm)
(Lead components)
The standard VCS or optional 37.5 mm, 27 mm or 18
mm VCS is not set in Placement data of general vision
components whose minimum pitch is 0.5 mm or wider,
but 6.5 mm or narrower.
*1
Placement of general vision
components (0.4 <= the
smallest pitch <0.5 mm) (Lead
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is 0.4 mm or wider, but narrower than 0.5
mm.
*1
Placement of general vision
components (0.3 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 27 mm or 18 mm VCS is not set in
Placement data of general vision components whose
minimum pitch is 0.3 mm or wider, but narrower than 0.4
mm.
*1
Placement of general vision
components (0.2 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 18 mm VCS is not set in Placement data of
general vision components whose minimum pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (15 < the smallest
pitch <= 22 mm) (Ball
components)
The standard VCS is not set in Placement data of vision
components whose minimum pitch is wider than 15 mm,
but 22 mm or narrower.
*1
Placement of vision
components (11 < the smallest
pitch <15 mm) (Ball
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Placement of vision
components (6.5 < the smallest
pitch <= 11 mm) (Ball
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of vision components
whose minimum pitch is wider than 6.5 mm, but 11 mm
or narrower.
*1
Vision data
Placement of vision
components (1.0 <= the
smallest pitch < 6.5 mm) (Ball
components)
The standard VCS optional 37.5 mm, 27 mm or 18 mm
VCS is not set in Placement data of vision components
whose minimum pitch is wider than 1.0 mm, but 6.5 mm
or narrower.
*1
*1: Items applicable to machines other than a KE-2010