KE2010.Instruction Manual.Ver.2.01,Rev.08.pdf - 第1164页
81 E500101 “Input range has been exceeded. The resumption positi on of a placement point is set outsi de of the possibl e range” [Cause] T he entered r esum ption position of a placem ent point exc eeded the input range.…
80
? : The name of the window that you failed to create.
[Treatment] There is a possibility that enough working space is not being saved. Please add
some more memory available.
E500002 “There is no memory enough <%s>”
[Cause] An error occurred while reading the data from or writing the date in the file.
? : An action that is a cause of the error
Memory
:
Getting the production program storage memory
Read File
:
Reading the production program in.
Write File
:
Writing into the production program.
LockFile
:
A lock for the file.
Free Memory
:
Releasing the production program storage memory.
? : Error code
9008
:
File open error
9009
:
File close error
9010
:
File reading error
9014
:
The file can not be found.
9020
:
Memory saving error
9021
:
Memory releasing error
9028
:
File in-use error
9029
:
File type error
9030
:
Parameter error
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500003 “File reading error”
[Cause] Failed to read the data from the file.
? : The name of the file you tried to read from.
[Treatment] Please re-install the system.
E500004 “The file can not be displayed <Err No : ?>”
[Cause] The wordpad that displays an error or a warning in the production program check
prior to a production can not be displayed.
?? : Error cause code
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500100 “Incorrect character has been input”
[Cause] You tried to enter incorrect data.
[Treatment] Please re-enter correct data.
81
E500101 “Input range has been exceeded. The resumption position of a
placement point is set outside of the possible range”
[Cause] The entered resumption position of a placement point exceeded the input range.
[Treatment] Please enter the value that is under the maximum number of placement points.
E500102 “Input range has been exceeded. (Input range: %ld - %ld)”
[Cause] The input value exceeded the input range.
? - ? : The maximum and minimum values of the input range.
[Treatment] Please enter a value that is within the input range.
E500200 “PWB data has not been completed”
[Cause] The production can not be started since the PWB data of the Production program
that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and complete the PWB data.
E500201 “Placement data has not been completed”
[Cause] The production can not be started since the Placement data of the Production
program that is currently loaded on the memory is incomplete. However,
‘complete’ here applies only to the placement data that will actually be placed (the
placement data that will be skipped is not included), and production programs
that are considered as ‘incomplete’ in the Production Program Editor may
become ‘complete’ in the production.
[Treatment] Please go to the Production Program Editor and complete the Placement data.
E500202 “Component data has not been completed”
[Cause] The error is likely to happen when starting a production by pressing the START
button on the operation panel. The production can not be started since the PWB
data of the Production program that is currently loaded on the memory is
incomplete.
[Treatment] Please go to the Production Program Editor and complete the PWB data.
E500203 “Pick-up data has not been completed”
[Causes] The production can not be started since the Pick data of the Production program
that is currently loaded on the memory is incomplete. However, ‘complete’ here
applies only to the pick data that will actually be picked (a pick data which is set to
“not use” is not included), and production programs that are considered as
‘incomplete’ in the Production Program Editor may become ‘complete’ in the
production.
[Treatment] Please go to the Production Program Editor and complete the Pick data.
E500204 “Mark data has not been completed”
[Cause] The production can not be started since the Mark data of the Production program
that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the BOC mark setting of the
PWB data and the IC mark setting of the Placement data.
82
E500205 “Vision data has not been completed”
[Cause] The production can not be started since the Vision data of the Production
program that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the Vision data.
E500206 “Teaching of acknowledgment of BOC mark has not been
completed”
[Cause] The Recognition teaching of BOC mark the Production program that is currently
loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the Recognition teaching in
the PWB data.
[Remarks
]
Please note that whether the recognition teaching of BOC marks is done or not
will not affect on the completion status of the PWB data.
E500207 “Teaching of acknowledgment of IC mark has not been completed”
[Cause] The Recognition teaching of IC mark the Production program that is currently
loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the IC teaching in the
Placement data.
[Remarks
]
In a normal production program, a placement data is considered as ‘incomplete’
when its recognition teaching of IC mark has not been done. There is a possibility
that the production program is broken when the error occurs.
E500208 “The production program breaks”
[Cause] Failed to read in the production program file.
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500210 “Auto. Select exists in the Pick data. Production can not be
executed”
[Cause] [Feed] in the Pick data is set to Auto. Select. The production can not be executed.
[Treatment] You need either to execute the Optimization in the Production Program Editor or
to set pick positions.
E500211 “There is no data which placement is specified”
[Cause] This message appears when the trial shot range is set to ‘specified placement
point’ on the Trial production dialog, but there is no placement data.
[Treatment] Please select other trial shot range or go back to the Production Program Editor
to examine the Placement data.
E500212 “There is no pick point on both left and right sides in Fully
Synchronized mode”
[Cause] There is a component which pick point exists only on one side.
[Treatment] Please go to the Production Program Editor and see the Pick data.