4 – 212 I f the system f ails to recognize a BOC m ark, the f ollowing dialog box appears on the screen. Figure 4.12. 3.1.3 BOC mark recognition error dialog box T o recog nize the BOC mar k ag ain, select one of the f o…

100%1 / 1361
4 – 211
When you press the <Start> button, the following dialog box appears on the screen
during BOC alignment operation.
To abort the operation for some reason, press the <Stop> button.
Figure 4.12.3.1.2 “BOC mark alignment” dialog box
1) State
Circuit no
The number of circuit being recognized is displayed here. This number is
indicated in the format: “current circuit number”/”total number of circuits”.
(Normally, only a BOC of the reference circuit is recognized.)
Station (available to a KE-2030 only)
The station which is recognizing a BOC mark is displayed here.
2) Progress
The progress bar indicates the progress of the current operation.
4 – 212
If the system fails to recognize a BOC mark, the following dialog box appears on the
screen.
Figure 4.12.3.1.3 BOC mark recognition error dialog box
To recognize the BOC mark again, select one of the following radio buttons displayed
in the “Restart Mode” column.
Re-try at same position.
Recognizes the BOC mark again without changing the current OCC camera
position.
Re-try at taught position.
Recognizes the BOC mark again at the position whose coordinates were taught
with the CAMERA button of the HOD. This item is available only after you
validate the result of teaching operation.
Use taught position as center.
Validates the position whose coordinates were taught with the CAMERA button of
the HOD as the actual center of the recognized BOC mark. This item is
available only after you validate the result of teaching operation.
To restart the BOC mark recognition operation after selecting one of the above radio
buttons, click the <Restart> button.
When you click the <Ignore> button, the system does not recognize a BOC mark at
each circuit/board hereinafter.
4 – 213
4.12.3.2 Mark - Feeder Bank (Front/Rear)
This command recognizes a feeder bank mark, then saves the coordinates which
were recognized and measured. These coordinates are used to correct coordinates
during teaching Pick data
To recognize a mark on the front feeder bank, select the [Front] command. To
recognize a mark on the rear feeder bank, select the [Rear] command.
(When you select either of these commands with a KE-2030, marks on the left or right
station are to be recognized twice.)
Figure 4.12.3.2.1 “The bank mark recognition confirmation” dialog box
If the system fails to recognize a bank mark, the following dialog box appears on the
screen. In this case, the recognition result is not saved. Select with which timing a
mark is to be recognized.
(1) The mark correction is not done to the bank descent.: A mark is not corrected
until the bank moves down.
(2) The mark correction will be done next time: A bank mark is recognized the next
time.
Figure 4.12.3.2.2 “The bank mark recognition error” dialog box