68 Q302001 ”Exi t machine setup. Set value is saved?” [Cause] You are ask ed if to save the param eter that was s et in Machine Setup. [Treatm ent] “YES” button will save the set value. “NO” button will not save the s et…

100%1 / 1361
67
E301054 “MTC/MTS can not be connected to 2000 series machines at the
same time”
[Cause] MTC and MTS can not be set at the same time.
[Treatment] Please disable one of them.
E301055 “An error on axes occurred”
[Cause] An error occurred while axes were traveling.
[Treatment] Please contact our technical service dept. for information.
E301056 “An error on XY axes occurred”
[Cause] An error occurred while XY axes were traveling.
[Treatment] Please contact our technical service dept. for information.
E301057 “An error on Z axis occurred”
[Cause] An error occurred while Z axis was traveling.
[Treatment] Please contact our technical service dept. for information.
E301058” “Specified 508 nozzle has not been assigned yet. Please execute
nozzle assignment”
[Cause] 508 nozzle is necessary to auto-teach MTC shuttle pick position to the machine,
but the 508 nozzle has not been assigned yet..
[Treatment] Please assign the 508 nozzle, then try auto-teaching.
E301059 “It was impossible to learn the height. Please checck out the
vacuum value”
[Cause] An abnormal matter happened while learning the height by vacuum.
[Treatment] Please check and see if the vacuum pressure is correct.
E301060 “DTS/MTS can not be connected to 2000 series machines at the
same time”
[Cause] DTS and MTS can not be set at the same time.
[Treatment] Please disable one of them.
E301061 “Feeder float detector can not be set only out position”
[Cause] You can not use the outer feeder float detectors only.
[Treatment] Please use the inner feeder float detectors only or use all the detectors at once.
Q302000 “Reset I/O?”
[Cause] You are asked if to set each I/O in the safety direction.
[Treatment] “YES” button will sets I/O in the safety direction.
“NO” button will discontinue to exit the Manual control.
68
Q302001 ”Exit machine setup. Set value is saved?”
[Cause] You are asked if to save the parameter that was set in Machine Setup.
[Treatment] “YES” button will save the set value.
“NO” button will not save the set value.
“Cancel” button will cancel your inquiry.
Q302002 “Error has occurred during automatic measurement of nozzle. Do
you interrupt automatic measurement?”
[Cause] An error occurred during the auto. nozzle measurement of ATC nozzle allocation.
You are asked if to abort the following ATC auto. measurement.
[Treatment] “YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302003 ”Return to home has not yet been completed. Return to home?”
[Cause] The axis has not returned to home yet. You are asked if to perform Home
returning.
[Treatment] “YES” button will perform the Home returning, and continue the process.
“NO” button will not perform the Home returning, but continue the process.
Q302004 “Error has occurred during nozzle installation. Move to parking
position?”
[Cause] A nozzle installation error of ATC nozzle allocation occurred. You are asked if to
move the head to the nozzle removal position.
[Treatment] “YES” button will move the head to the nozzle removal position, and continue the
process.
“NO” button will not move the head to the nozzle removal position, but continue
the process.
Q302005 “Extend shuttle?”
[Cause] You are asked if to draw a shuttle out of MTC when teaching the MTC shuttle
pick position to the machine.
[Treatment] “YES” button will draw the shuttle from MTC, and get in the teaching mode.
“NO” button will no draw the shuttle from MTC, but get in the teaching mode.
Q302006 “Do you interrupt automatic measurement?”
[Cause] STOP switch was pressed while nozzle were automatically assigned. You are
asked if to abort the auto. measurement.
[Treatment] “YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302007 “A nozzle is fixed to %s. Do you want to auto-return the nozzle?"
[Cause] With a nozzle on the head, the ? head in the Use unit was changed to “not use”
from “use” You are asked if to return the nozzle to ATC before enabling the
change.
[Treatment] “YES” button will return the nozzle installed on the head.
“NO” button will enable the change with the nozzle on the head. When you
choose “NO”, you need to cancel the nozzle allocation in the ‘ATC nozzle
allocation’.
69
Q302008 “Extend MTS mark?”
[Cause] In the MTS assemblage position offset, you are asked if to draw a bank mark
from MTS when teaching the mark position to the machine.
[Treatment] “YES” button will draw the bank mark out.
“NO” button will not draw the bank mark out.
Q302009 “Vacuum Calibration has been set already. (ATC No:%s) Would
you like to disable the setting?
[Cause] In the ATC nozzle allocation, you are asked if to disable the settings for current
when you try to specify a vacuum calibration to the current ATC even if the
calibration unit has been set to another ATC.
?:Current Vacuum Calibration unit setting ATC No.
[Treatment] ”YES” button will disable the existing AT, and sets a vacuum calibration unit to the
current ATC.
“NO” button will not do anything to the current ATC.
Q302010 “An error occurred during Auto. measuring nozzles. Would you
like to discontinue the Auto. measuring on the left station?”
[Cause] An error occurred on the left station during the auto. nozzle measurement of ATC
nozzle allocation. You are asked if to abort the following ATC Auto.
measurement.
[Treatment] “YES” button will abort the auto. nozzle measurement on the left station.
“NO” button will continue the auto. nozzle measurement on the left station.
Q302011 “An error occurred while installing nozzles. Would you like to move
to the parking position? [Error occurs] ? [Error No.] ? ?[ Error
Info.] ???"
[Cause] A nozzle installation error of ATC nozzle allocation occurred. You are asked if to
move the head to the nozzle removal position.
?: A code which shows where the error occurred
??: Error code
???: Error details code
[Treatment] “Yes” button will move the axis to the nozzle removal position, and continue the
process.
“NO” button will not move the axis to the nozzle removal position, but continue the
process.
Q302012 “Move Z axis to where nozzles are taken off. Is that OK?”
[Cause] A nozzle installation error of ATC nozzle allocation occurred. You are asked if to
move the head to the nozzle removal position.
[Treatment] “Yes” button will move the axis to the nozzle removal position, and continue the
process.
“NO” button will not move the axis to the nozzle removal position, but continue the
process.
Q302013 “Return Z axis to Laser height position. Is that OK?”
[Cause] When a nozzle installation error of ATC nozzle allocation occurred, you are asked
if to move the head to the laser height after the head gets to the nozzle removal
position.
[Treatment] “YES” button will move the head to the laser height, and continue the process.
“NO” button will not move the head to the laser height but continue the process.