48 E240011 “The station i s different ” [Cause] T his er ror occ urs when the side the HOD devic e is on is wrong when teaching. [Treatm ent] Please check and s ee which device (left or right) to use. E240012 “Specif ied…
47
[Treatment] Please check and see if the axis can move properly with Manual control.
E240001 “The axis cannot be moved to escape point”
[Cause] You could not move the axis to the Escape point.
[Treatment] Please check and see if the axis can move properly with Manual control.
E240002 “Yc table cannot be moved”
[Cause] You could not move the Yc table.
[Treatment] Please check and see if the Yc table can move properly with Manual control.
E240003 “The axis margin out of range. It is not possible to operation”
[Cause] You could not move the axis since it went out of its movable range.
[Treatment] Please check and see if its coordinates are correct.
E240004 “The interrupt which was not able to operate was detected. The
trace is ended”
[Cause] The process was forcibly aborted since an interruption, such as axis alarm and
Emergency STOP, that stops every kind of actions was detected.
[Treatment] Please check and see if any alarms occurred, and deal with causes of the alarm.
E240005 “The area sensor was detected.
Please remove the sensor
reaction factor”
[Cause] Tracing got paused since the area sensor detected something.
[Treatment] Please removed a factor detected by the sensor, and resume tracing.
E240006 “The feeder float sensor was detected. Please remove the sensor
reaction factor”
[Cause] Tracing got paused since the feeder float sensor detected something.
[Treatment] Please removed a factor detected by the sensor, and resume tracing.
E240007 “Input is mistake”
[Cause] Something was wrong with the characters when you hit Enter key to define
characters.
[Treatment] Please re-enter characters
E240008 “There is no data previous”
[Cause] This error occurs when there is no data ahead to trace.
[Treatment] Check only
E240009 “There is no data next”
[Cause] This error occurs when there is no data behind to trace.
[Treatment] Check only
E240010 “Specified device cannot be used”
[Cause] The specified device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
48
E240011 “The station is different”
[Cause] This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment] Please check and see which device (left or right) to use.
E240012 “Specified position not move”
[Cause] You could not move the axis to the specified position since the axis went out of its
movable range.
[Treatment] Please check and see if the coordinates are correct.
E240013 “The origin point return is non-completion”
[Cause] Home returning has not been complete yet.
[Treatment] Please hit the ORIGIN button to perform the Home returning, and try the process
again.
E240014 “The Left OCC device is set in unused by the setup”
[Cause] The Left OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E240015 “The Right OCC device is set in unused by the setup”
[Cause] The Right OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E240016 “The HMS device is set in unused by the setup”
[Cause] The HMS device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
Q240500 “End tracking?”
[Cause] You are asked if to end the tracking process.
[Treatment] If you want to end the process, press ‘Yes’. If not, press ‘No’.
E241000 “Memory allocation error”
[Cause] Failed to save the work area necessary to run a program or to create a window
due to the shortage of memory
[Treatment] Please increase some memory available by exiting unnecessary applications.
49
E241001 “Specified device cannot be used”
[Cause] You could not go into the teaching mode since the device selected by HOD is not
installed or is set to “not use”.
[Treatment] Please check the installation setting (an option of MS parameter) or the use
setting (Use unit of Machine Setup) of the selected device, and reselect a device
available.
E241002 “The station is different”
[Cause] You could not go into the teaching mode since the device selected by HOD and
the Pick data specify different stations to use.
[Treatment] Please reselect a correct device.
E241003 “Specified position not move”
[Cause] You could not go into the teaching mode since you could not move to the
specified position with the device selected by HOD.
[Treatment] Please reselect a device that is available to move to the specified position.
E241004 “The input value is illegal (%s)”
[Cause] This is a program error. The specified value in the dialog became an illegal value.
? : A dialog item that is a cause of the error.
[Treatment] Please close the dialog and try again. If the error occurs again even after the retry,
please contact our technical service dept. for information.
E241005 “Index of component data has irregularities (%d)”
[Cause] The index number of the Component data is illegal. There is a possibility that the
production program is broken.
? : The index number of the Component data.
[Treatment] Please examine the production program.
E241008 “Supply of the component is not assign”
[Cause] ‘Component package’ has not been set in the Component data.
[Treatment] Please set ‘Component package’ in the Component data.
E241009 “Centering of the component is no laser”
[Cause] ‘Centering method’ has not been set to Laser centering in the Component data.
[Treatment] Please set ‘Centering method’ to Laser centering in the Component data.
E241010 “Centering of the component is not assign”
[Cause] ‘Centering method’ has not been set in the Component data.
[Treatment] Please specify ‘Centering method’ in the Component data.
E241011 “No pick data”
[Cause] There is no Pick data that is linked to the Component data.
[Treatment] Please examine the production program.