171 ④ Som ething is wrong with the movem ent of the ATC s lide plate. In this case, the f ollowing cases c an be possible. A) The speed c ontroller of the slide plate driving c ylinder is wrung to its minim um lim it. Pl…

100%1 / 1361
170
change the coordinates or the height, please select [Setup(S)] [MS
parameter] and follow the Maintenance manual. For MS parameter, it is
limited that who can change the parameter by the user level setting.
E610039 “The nozzle is too long (over 1.0mm). Please check the nozzle
installation status”
[Cause] When checking installation status after a nozzle is installed, the nozzle was
detected at a position where the nozzle is not supposed to be detected if it is
installed properly. Possible causes are that nozzles were changed manually, that
the nozzle is not installed correctly, or that the window of the laser measurement
unit is dirty.
[Treatment] 1. If a nozzle of the right nozzle number is properly installed.
Although the nozzle has the right nozzle number, there is a possibility that
a different nozzle was installed manually. Please perform the ATC nozzle
allocation and get the right nozzle length again. The ATC nozzle allocation
can be performed by selecting [Machine Setup] from the menu bar and
then [Setting Group(G)] [ATC Nozzle Allocation(A)].
There is a possibility that the measurement height of the laser sensor
changed due to the filter change or cleaning of the nozzle outer shaft (the
installation part of a head). If the error occurs after changing or cleaning a
filter attached to the nozzle outer shaft, please examine if the filter is
installed correctly.
There is a possibility that the window of the laser sensor is dirty. Please
clean the window of the sensor. You can check the dirt of the window with
the following procedures. Select [Manual Control] from the menu bar, and
then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in ‘Control’ unit, and then select ‘Image displaying’ from
‘Control Item’ frame. By enabling ON, an image data will be shown.
If the treatments above do not work, you need to change the laser
measurement height. Please select [Setup(S)] and then [Self-Calibration]
[Setting Group(S)] [Laser sensor height(L)] to get the laser height of the
concerned head, or please select [MS Parameter] and change the height
following the Maintenance manual. The height change by self calibration
or MS parameter limits setters by the user level setting.
2. If the nozzle is not installed properly.
Take the nozzle off once and reset it on ATC. The following causes are
possibly for why the nozzle did not get installed properly.
There is oily stuff such as grease between the brim of the nozzle that
touches ATC and the installation side of ATC. If there is any oily stuff,
please remove it.
There is an abnormal nozzle. Please examine if there is any obstructions
on the installation part on the head, or if it is damaged or deformed
The nozzle outer shaft (the installation part of a head) is not set correctly.
Especially when the error occurs after changing or cleaning a filter
attached to the nozzle outer shaft, please examine if the outer shaft is
installed correctly.
171
Something is wrong with the movement of the ATC slide plate. In this
case, the following cases can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its
minimum limit. Please loosen the speed controller of the slide plate
driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong.
There is a possibility that the sensor gets ON before the slide plate
fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being
opened/closed. Please examine if there is anything caught in near
the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct.
Please examine if the air pipe is properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the
connector part of the slide plate plays too much. Please examine if
the nut is tightened up enough.
The ATC coordinates or the nozzle change height is not correct. If you
change the coordinates or the height, please select [Setup(S)] [MS
parameter] and follow the Maintenance manual. For MS parameter, it is
limited that who can change the parameter by the user level setting.
E610040 “The nozzle is too short (over 10.0mm). Please check the nozzle”
[Cause] When checking installation status after a nozzle is installed, the nozzle was
detected at a position where the nozzle is not supposed to e detected if it is
installed properly. A nozzle which is shorter than a normal nozzle is installed.
[Treatment] There is a possibility that the nozzle is damaged. Please examine the nozzle.
E610041 “The nozzle width does not meet that of standard nozzle”
[Cause] The outer shape of auto-recognized nozzle did not coincide with that of the
standard nozzle. Therefore, nozzle number could not be et automatically. As a
temporary nozzle number, the smallest option nozzle number is set. The cause
may be that a particular nozzle is set or that the window of the laser sensor is
dirty.
[Treatment] 1. If a particular nozzle is set.
If a nozzle number of the particular nozzle is the same as that of another
particular nozzle that has already been set, please re-enter the concerned
nozzle number.
2. If a standard nozzle is set.
There is a possibility that the window of the laser sensor is dirty. Please
clean the window of the sensor. You can check the dirt of the window with
the following procedures. Select [Manual Control] from the menu bar, and
then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in ‘Control’ unit, and then select ‘Image displaying’ from
‘Control Item’ frame. By enabling ON, an image data will be shown.
There is a possibility that something is on around the tip of the nozzle so
that the right nozzle width can not be detected. Please examine the
nozzle.
If any of the treatments above do not apply and if you are sure that the
nozzle is a standard nozzle, please enter its nozzle number manually.
172
E610042 “A shadow is detected while nozzle detection after returning
nozzles”
[Cause] A nozzle was detected at a position where normal nozzles are not supposed to be
detected in the installation status checking which is performed after the nozzle
returning. There is a possibility that the nozzle could not be returned right or the
window of the laser sensor is dirty.
[Treatment] 1. If the nozzle was returned properly
There is a possibility that the window of the laser sensor is dirty. Please clean
the window of the sensor. You can check the dirt of the window with the
following procedures. Select [Manual Control] from the menu bar, and then
select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned laser
sensor in ‘Control’ unit, and then select ‘Image displaying’ from ‘Control Item
frame. By enabling ON, an image data will be shown.
2. If the nozzle was not returned properly.
Please take the nozzle off the head part and set it on ATC. The following
causes are possible for why the nozzle could not be returned correctly.
There is an abnormal nozzle. Please examine if there is any obstructions
on the installation part on the head, or if it is damaged or deformed
Something is wrong with the movement of the ATC slide plate. In this
case, the following cases can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its
minimum limit. Please loosen the speed controller of the slide plate
driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong.
There is a possibility that the sensor gets ON before the slide plate
fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being
opened/closed. Please examine if there is anything caught in near
the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct.
Please examine if the air pipe is properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the
connector part of the slide plate plays too much. Please examine if
the nut is tightened up enough.
The ATC coordinates or the nozzle change height is not correct. If you
change the coordinates or the height, please select [Setup(S)] [MS
parameter] and follow the Maintenance manual. For MS parameter, it is
limited that who can change the parameter by the user level setting.
E610043 “Head traveling coordinates are within the head interference
range(SLOW)”
[Cause] The left and right heads can not move at high speed since they interfere each
other when they travel to the specified ATC position simultaneously. Some
program versions in the machine may be clashing with each other.
[Treatment] Please turn off the power supply of your machine and reboot it.
If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.