6 − 146 (1) Setting check conditions If you enter Single check mode when a continuous check err or occurs, the following "I nspection" dialog box appears on t he screen. Inspection di alog box 1) Component of i…

100%1 / 1361
6 145
4) End of continuous check
When the system finishes checking all components which satisfy the
conditions you specified, the following dialog box appears on the screen.
Figure 6.7.2.5.2.6 "Information - end of Continuous laser position
inspection" dialog box
6.7.2.5.3 Single inspection
When you click the <INSP.> button (F10 key), the system starts checking a
component. When it finishes checking the component, the result appears on
the screen.
When you click the <MEAS.> button (F10 key), the system starts measuring a
component. When it finishes measuring a component, the result appears on
the screen.
On the "Inspection" screen, you can manually enter the pick-up position or use
the teaching function to enter it. When you check the check box "The taught
result is reflected in the pick data.", the taught data is stored into Pick data.
On the "Laser position measurement" screen, pressing the NEXT or
PREVIOUS key of the HOD or the F5 or F6 key moves the component pick-up
position to the alternative component.
In Continuous check mode, pressing the <START> switch resumes the
continuous check.
6 146
(1) Setting check conditions
If you enter Single check mode when a continuous check error occurs, the
following "Inspection" dialog box appears on the screen.
Inspection dialog box
1) Component of insp. (inspection)
The description of a component to be inspected and its pick-up position
are displayed here.
2) Inspected value
The laser height of a component to be inspected ("LA Pos") and its height
(Compo. height) are displayed here.
6 147
3) <MEAS.> button
This button measures the laser height.
(See Section 6.7.2.5.4 "Measuring laser height".)
4) Pickup position
The pick-up position of a component is displayed here. You can change
the pick-up position to the previous alternative component or next one.
<FEED> button
This button knocks a feeder (other than a 32-mm paper tape feeder)
once to feed a component.
"The taught results reflected in the pick data."
Check this check box if you want to store the result taught by the
HOD device into Pick data. When unchecked, only the coordinates
of the current pick-up position are applied to Pick data.
5) Result of inspection
After checking laser height, the result is displayed in this "Result of
inspection" column. The "Short side" and the "Log side" indicate the data
obtained when the system detects the minimum width of a component for
the first time and second time respectively. These values are effective
only when each status of the "Short side" and "Long side" is "OK".
Status
OK: Centering is done successfully.
Number: Centering failed. (Each number indicates the error code
number of the laser status.)
Outline
The width of a component which is detected with laser when the
component is centered successfully is displayed here.
Angle