62 E292000 “No regist ered data” [Cause] T he f ollowing procedures were tak en place when the num ber of the registered issue of Mark Database is zero. 1. Pres s [Renam e(C)] button or [Delete(D)] button on the Mark Dat…

100%1 / 1361
61
Q291501 “Operation interruption. Please push ‘No’ when discontinuing.
‘Yes’ when continuing”
[Cause] The operation was aborted since STOP button was pressed.
[Treatment] If you want continue the operation, press ‘Yes’. If not, press ‘No’.
Q291502 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291503 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291504 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291505 “Unit is moved to escape point. Please confirm safety.
Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291506 “Conveyor width is moved. Please remove handknob and PWB from
conveyor. | Please push ‘No’ when discontinuing. ‘Yes’ when
continuing”
[Cause] You are asked if to perform the safety check by removing PWBs and a handknob
from the conveyor since the conveyor width is adjusted.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291507 “The origin point return of automatic conveyor width adjustment is
non-completion. Continue anyway? Please push ‘No’ when
discontinue. ‘Yes’ when continuing”
[Cause] You are asked if to perform the Home returning of the Auto. PWB Width
Alignment Control since its Home returning has not been complete yet.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
62
E292000 “No registered data”
[Cause] The following procedures were taken place when the number of the registered
issue of Mark Database is zero.
1. Press [Rename(C)] button or [Delete(D)] button on the Mark Database
Management screen.
2. Press [Replace(A)] button on the Registration Mark Database screen.
3. Press [Copy(C)] button on the Vision Copy screen.
[Treatment] The procedures above can not be performed when there is no registry in the
Mark Database.
E292001 “Please select the mark”
[Cause] 1. Although [Rename (C)] button or [Delete(D)] button screen were pressed on
the Mark Database Management screen, there is no selected mark to be an
object of the action.
2. Although [Copy(C)] button was pressed on the Vision Copy screen, there is no
selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of each action.
E292002 “Registration number was exceeded”
[Cause] As the maximum number of registration is 100, you can not register any new data
in the Mark Database.
[Treatment] Please delete unnecessary marks on the Mark Database Management screen.
E292003 “The mark of the same registration name exists”
[Cause] 1. On the Mark Data name change screen which is shown when pressing
[Rename(C)] button on the Mark Database Management screen, a name
which was entered as “a name after the change” has already been registered
in the Mark Database.
2. When pressing [Add New(N)] button or [Replace(A)] button on the
Registration Mark Database screen, a name which was entered as “a name to
register” has already been registered in the Mark Database.
[Treatment] Please enter the names that have not been registered in the Mark Database yet.
E292004 “Please input the registration name”
[Cause] 1. Although [OK] button was pressed on the Mark Data name change screen that
is shown when pressing [Rename(C )] button on the Mark Database
Management screen, “a name after the change” has not been entered yet.
2. Although [Add new(N)] button or [Replace(A)] button was pressed on the Mark
Database register screen, “a name to register” has not been entered yet.
[Treatment] Please enter a mark name.
E292005 “Please select the registered area”
[Cause] Although [Replace(A)] button was pressed on the Mark Database Registration
screen, there is no selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of overwriting.
Q292501 “The selected mark data is deleted. Is it good?”
[Cause] This message appears in order to confirm you if to delete the data when
pressing[Delete(D)] button on the Mark Database Management screen.
[Treatment] If you want to delete the mark, press [OK] button. If not, press [Cancel] button.
E301000 “Memory allocation error”
[Cause] The working space can not be saved.
63
[Treatment] Please add some more memory available to save the working space.
E301001 “There is no input character”
[Cause] There was no character when you hit Enter key to define characters.
[Treatment] Please enter characters.
E301002 “Input character has irregularities”
[Cause] The letter strings had irregularities when defining the input.
[Treatment] Please enter proper characters.
E301003 “Input value exceeds predetermined data range. (Data range:%s)”
[Cause] The value when defining the input exceeded the input range.
[Treatment] Please enter the values that are within the range.
E301012 “An error occurred while measuring nozzle height by Laser”
[Cause] An error occurred during the laser height measurement by laser.
[Treatment] Something might be wrong with Laser alignment. Please check it.
E301015 “Specify user’s individual nozzle No.”
[Cause] When measuring the width of a nozzle’s outer shape by laser, the output does not
coincide with that of a standard nozzle. Therefore, the nozzle number can not be
set automatically. As a temporary nozzle No., the smallest nozzle number (530)
of option nozzles is set for the nozzle.
[Treatment] If the nozzle is a standard nozzle, please measure it again. If the same result
comes out, something might be wrong with the nozzle shape. Please check the
nozzle. If the nozzle is an option nozzle, the nozzle number set is just a temporary
number and might be wrong. Please set a nozzle number for the nozzle again. If
you measure the nozzle again after set a nozzle number for the nozzle, the
temporary nozzle number will be set again.
E301016 “An error occurred while taking nozzles off”
[Cause] This message occurs when the machine determines that the nozzle is still on the
head even despite the nozzle removal took place.
[Treatment] If the nozzle is not on the head, the laser might be too dirty to work properly.
Please clean the laser. Also, please check and see if the slide plate can slide
properly or the sensor works properly with Manual control. If the slide plate or the
sensor does not work well, something might be broken. Please take a note of the
error No. and contact our technical service dept. for information.
E301017 “Selected device can not move to this position. Please reselect
other device on HOD”
[Cause] You cannot go into the teaching mode since you can not move to the speicified
position with the device selected by HOD.
[Treatment] Please reselect a device available.