177
E610052 “ATC X coordinate is abnormal”
[Cause] The head could not move to the specified ATC position. Some program versions
in the machine may be clashing with each other.
[Treatment] • Please turn off the power supply of your machine and reboot it.
• If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
• If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.
E610083 “Measured width of the nozzle does not coincide with the assigned
width. Machine does not return the nozzle because of possible
damage to the nozzle. Check how the nozzle is attached. Press
<No> to allow the machine to return the nozzle.”
[Cause]
The outer shape of a nozzle taken up from the ATC does not meet that of the
nozzle assigned in Machine setup.
The nozzle may be attached improperly.
The attached nozzle is different from what assigned to the ATC.
The laser sensor has failed.
[Treatment]
Check if the attached nozzle is different from what assigned to the ATC.
If the assignment is correct, then check how the nozzle is attached. If the nozzle is
attached improperly, remove it manually.
If the nozzle is properly attached, select “No.” The machine will return the nozzle
automatically.
If no problems are found in the checks above, check the laser sensor using an
appropriate command in Laser control of Manual control.
When the laser sensor malfunctions, turn the machine power OFF, and then
restart it.
If the error persists despite the above restart, contact our service engineer or the
agency to counter a possible failure.
E610084 “Measured width of the nozzle does not coincide with the assigned
width. Machine does not return the nozzle because of possible
damage to the nozzle. Remove and return the nozzle manually.”
[Cause] The outer shape of a nozzle taken up from the ATC does not meet that of the
nozzle assigned in Machine setup.
The nozzle may be attached improperly.
The attached nozzle is different from what assigned to the ATC.
The laser sensor has failed.
[Treatment] Check if the attached nozzle is different from what assigned to the ATC.
If the assignment is correct, then check how the nozzle is attached. If the nozzle
is attached improperly, remove it manually.
If the nozzle is properly attached, select “No.” The machine will return the nozzle
automatically.
If no problems are found in the checks above, check the laser sensor using an
appropriate command in Laser control of Manual control.
When the laser sensor malfunctions, turn the machine power OFF, and then
restart it.
If the error persists despite the above restart, contact our service engineer or
the agency to counter a possible failure.
E610100 “The Vacuum calibration has not been installed”
[Cause] The installation position of the vacuum calibration has not been set.
[Treatment] If the vacuum calibration unit has not been installed on ATC, please install it.
You can set the installation position of the vacuum calibration as follows.
Please select [Machine Setup] from the menu bar, and then [Setting Group(G)]
178
[ATC Nozzle Allocation(A)]. If you right-click the mouse on the nozzle type of the
ATC number on which the vacuum calibration unit is installed, a list box is shown.
Select ‘VacUnit’ in there.
E610200 “Emergency Stop SW occurred”
[Cause] The Emergency Stop SW was pressed.
[Treatment] Please unlock the Emergency Stop SW and hit the OK key.
E610201 “Area sensorF ON occurred”
[Cause] The area sensor on the front side got ON.
[Treatment] Please hit the OK key and then perform the Home returning.
E610202 “Area sensorR ON occurred”
[Cause] The area sensor on the rear side got ON.
[Treatment] Please hit the OK key and then perform the Home returning.
E610203 “Cover open sensor ON occurred”
[Cause] The Safety cover is open.
[Treatment] Please close the Safety cover.
179
E610204 “Feeder floatation sensor ON occurred”
[Cause] The Feeder floatation sensor detected something.
[Treatment] The error occurs when the Feeder floatation sensor is interrupted. If there is
anything that interrupts the sensor, please remove it.
If the error occurs when there is nothing to interrupt the sensor, the light axis of
the Feeder floatation sensor may not be aligned well. Please examine if the light
emitted from the sensor is received by its light receiver properly. If the light is
received properly, the red and green LEDs on the sensor get on.
This error also occurs when the Feeder floatation sensor itself or MCM board in
the sensor is broken. There is a great possibility that the sensor itself or the MCM
board in the sensor is broken when this error keeps happening even if you adjust
the alignment of the light axis. If you want to avoid the error temporarily to
continue the production, please select [Machine Setup] from the menu bar, and
then [Setting Group(G)] [Use Unit(D)]. Please the tab of [Use Unit1] and disable
the checkbox of the Feeder floatation sensor.
Caution! If you do not use the Feeder floatation sensor for your production, make
sure that nothing interrupts the sensor. If a head should clash with an obstruction,
that may cause a serious accident.
E610205 “+X limit occurred”
[Cause] The head is on the +limit sensor which is on the right side of X axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.
E610206 “-X limit occurred”
[Cause] The head is on the -limit sensor which is on the left side of X axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.
E610207 “+XR limit occurred”
[Cause] The right head is on the +limit sensor which is on the right side of X axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.
E610208 “-XR limit occurred”
[Cause] The right head is on the -limit sensor which is around the center of X axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.
E610209 “+Y limit occurred”
[Cause] The head is on the +limit sensor (rear side) which is on the Y axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.
E610210 “-Y limit occurred”
[Cause] The head is on the -limit sensor (front side) which is on the Y axis.
[Treatment] Please get the head off the limit sensor, and then perform the Home returning.