Chapter 2 Inspection Programming
2-78
2.4.6.3 Deleting from Component Number Group
A component number is deleted from a component number group.
1.
Select a component type.
Select a component type from the [Component Type] pull-down
menu.
2.
Select a component number group.
3.
Select a component number.
Unselect the [Display component number not belonging to group]
check box, and select a component number you want to delete from
the selected component number group to which the component
number belongs.
4.
Delete from the component number group.
Click [Delete from Group] to delete the component number from the
component number group.
When a component number is deleted from a component
number group, the setting of the component number group is
succeeded to the component number. Be careful that the
original setting of the component number before being added
to the group is not restored.
A component number registered 1st to the component number
group cannot be deleted from the group. To delete the 1st
registered component number, delete the group first then
create and register the group again.

2.5 Registering the Component Number Model
2-79
書式変更: フォント : (日) MS ゴシッ
ク, 10 pt, 文字間隔広く /文字間隔狭く
(なし)
削除: Registering the Component Numbe
r Model
2.5 Registering the Component Number Model
Calculate the model for each component number and register the component information in the
library.
Details of the information registered are the color parameter information needed for the 2D
inspection logic and the height information and projector’s light intensity needed for the 3D
inspection logic.
Model calculation refers to the automatic extraction of the characteristic parameters to detect
the colors and shapes of the component and electrodes.
1.
Select the "Extract Parameters (Auto)" tab.
2.
Select the component number in the Component Number List.
The thumbnail images of the currently selected component and all
the components with the selected component number are displayed
in the image display area. If you select a component number
belonging to a component number group, all the thumbnail images
of the component number group are displayed.
When the button is (locked), click to change the
component number state to not locked .
Only the image for the component numbers with the right end
progress signal bar lit ( or ) can be selected. To redo
the model calculation for the comonent numbers with lit right
end signal bar, click [Delete].
Click button in the Image Operation tool bar to display a
list of component thumbnail images in the image display area.
Refer to "2.1.2 Configuration of the Editing Screen" for the
image operation buttons.
Operation

Chapter 2 Inspection Programming
2-80
3.
Check each component thumbnail image to determine if the image
and windows are aligned. If not, adjust the positions and sizes of
the windows.
Click a component thumbnail image or a component in the
Component Image List to select it. The field of vision on the PCB
image moves to the selected component.
Size adjustment is only possible for land windows.
The position of the Component Body Window and electrode
windows cannot be adjusted separately.
Refer to "2.1.3 Image Display Area Operation" for the image
display area operation.
4.
Select the component thumbnail image to use for model calculation
and click the corresponding checkbox in the Component Image List
or the checkbox next to the component thumbnail image.
The checkboxes for the components selected in inspection
registration are selected by default.
It is automatically judged by the destination setting of the
component of the inspection program which captured the image
if the checkboxes on the applicable image list are checked ON
or OFF. The components not included in the destination
program are checked OFF. For the components included in the
destination program, only the images of the inspection PCB
captured by the destination program are checked ON. However,
if images are present only in the master inspection program, the
PCB images in the master inspection program are checked ON.
Multiple images can be selected. Clicking the checkbox at the
header in the Component Image List can select all the images
(checkboxes) simultaneously.
For more precise extraction of characteristic parameters,
select a good component image for the model. If there are
multiple candidates with a slight difference e.g. in the electrode
color, select them all to enhance extraction precision.
5.
Repeat Steps 2 to 4 for the component numbers with no image
specified yet.