Omron V-TS Teaching Manual.pdf.pdf - 第333页

Appendix 9. Land Insp ection Adjustm ent Procedure a- 56 The details of the procedure f or land error adjustm ent are as f ollows: For details o f land error , refer t o P5-17 section 5.10 “ Land Error ” of the i nspect …

100%1 / 350
Appendix 9. Land Inspection Adjustment Procedure
a-55
Inspection result
Component image (PCB test)
Normal (land error
overlooked)
Cause
Confirmation/repair method
When position does not match between the actual land and extracted land:
The land window is not positioned
appropriately.
Refer to Appendix 7.2.
The land window of the peripheral
components of the applicable component is
not positioned appropriately.
Refer to Appendix 7.2.
The fiducial correction is not appropriate.
Refer to Appendix 7.1.
The position correction color is not
appropriate.
Refer to Appendix 7.2.
When position does not match between the actual component (electrode) and extracted component
(electrode):
The component extraction is not positioned
appropriately.
Refer to Appendix 7.5.
The electrode tip extraction is not positioned
appropriately.
Refer to Appendix 7.7.
The electrode side is not extracted in an
appropriate position.
Refer to Appendix 7.6.
The electrode window is not sized
appropriately.
Refer to Appendix 7.5.
The inspection area of land error is not
appropriate.
1) Move to the “Criteria Setting” tab.
2) Select “Inspection Criteria” - “Land Exposure”,
and click the [Model Editing] button (*Image to be
pasted).
3) Select the fault component, click the * button, and
select the area in which the characteristic of the fault
appears large.
4) Click the * button, and select the area in which the
characteristic of the fault does not appear (*Image to
be pasted).
The land error color is not set appropriately.
1) Move to the “Criteria Setting” tab.
2) Select “Inspection Criteria” - “Land Exposure”,
and click the [Model Editing] button (*Image to be
pasted).
3) Select the fault component and edit characteristic
parameters using the color table editing tool so that
the color of the fault is extracted (*Image to be
pasted).
The inspection criteria are not set
appropriately.
Refer to Appendix 10.1.
Appendix 9. Land Inspection Adjustment Procedure
a-56
The details of the procedure for land error adjustment are as follows:
For details of land error, refer to P5-17 section 5.10 Land Error of the inspection logic
manual.
This section hereafter describes the adjustment procedure for false call minimization.
Operation procedure
1. Check the land error checkbox.
2. Check the Relieve wetting inspection checkbox.
3. Set the inspection area on the area where the characteristic of OK product appears.
OK product example
Inspection area setting example
Appendix 9. Land Inspection Adjustment Procedure
a-57
4. Add characteristic quantity of the area other than the inspection area using the pen tool .
Exclude the characteristic quantity of the inspection area using the eraser tool .
5. Change the judgment criteria of land error so that false call is minimized.
This section hereafter describes the adjustment procedure to eliminate overlooking.
Operation procedure
1. Check the land error inspection checkbox.