Chapter 2 Inspection Programming
2-106
2.8.4 Displaying Inspection Detailed Result
This section shows the procedure to display the detailed result for an individual component.
1.
Select the component to check its detailed result in the Detailed
Result list and click [Detailed Result].
2.
The Detailed Result dialog appears, showing the set value,
measured value and judgment result.
If other component is selected while the dialog is open, the
dialog display is updated with the detailed result for the
selected component.
In the Detailed Result dialog, criterion values can be changed
and inspection values can be set ON/OFF.
Operation
2.8 PCB Testing/Result Check
2-107
2.8.5 Modifying Inspection Criteria
This section shows the procedure to modify the inspection criteria of the components where a
false call is output, by the unit of component number or component.
1.
Select the component in the Detailed Result list, and click [Criteria
Setting (Product No.)] or [Criteria Setting (Individual Component)].
2.
The display switches to the Inspection Criteria screen.
[Criteria Setting (Product No.)] [Criteria Setting (Individual Component)]
The screen displays the component selected in the result check
screen.
The inspection result for the individual windows of the displayed
component is shown in either of the "OK" or Fault Name descriptions,
together with the measured value of each inspection item and its
judgment (OK or NG).
[Criteria Setting (Product Number)]
Operation
Chapter 2 Inspection Programming
2-108
The Inspection Criteria Setting screen for a component number
displays the result ("OK" or Fault Name) in the Judge column in the
Component Number List.
3.
Adjust the position and size of the windows where an inspection
fault is output as required.
4.
Select the inspection item to modify, and change the inspection
criteria or edit the model.
The changed criteria values replace the old values in the library
when the inspection program is saved in the library.
Refer to "2.6.1 Criteria Setting (Product No.)" for criteria value
editing by the unit of component number, and "2.6.2 Criteria
Setting (Individual Component)" for the same by the unit of
individual component.
If the detected position does not match the image, editing of the
component top color or electrode color (model editing
operation) is required prior to changing the criteria value.
Refer to P2-135 "2.15.3 Editing a Model" for the model editing
procedure.