Chapter 2 Inspection Programming
2-30
Width (mm)
Enter the horizontal PCB size (Unit: mm).)
A value in the range of 50.00 to 510.00, up to two decimal
places can be entered.
The width cannot be changed once specified.
Height (mm)
Enter the vertical PCB size (Unit: mm).
A value in the range of 50.00 to 460.00, up to two decimal
places can be entered.
The height cannot be changed once specified.
The offset value can be changed after it is set, depending on
the PCB variations. The offset value can be specified up to the
first decimal place within the range from -0.5 to 0.5, which is
retained in individual inspection programs.
Refer to "2.18.5 Renaming an Inspection Program" for
the procedure to change the value.
Inspection Program Information
Inspection Machine
Select the inspection machine to use for capturing the PCB image
in the pull-down menu.
Inspection Program Name
Enter the name of a new inspection program within 48 single-byte
alphanumeric characters/symbols.
Symbols that can be used: ! # $ % & ' ( ) - = ^
~
@`[ { ;+ } ] ,._
Both upper and lower case alphabet characters can be used.
However, they are not distinguished.
式変更: フォント : Arial
削除: Renaming an Inspection Program
2.2 Creating a New Inspection Program
2-31
式変更: フォント : () MS シッ
ク, 10 pt
削除: Creating a New Inspection Progra
m
Inspection Surface
Select the inspection PCB surface.
Land height offset (mm)
Enter the height difference between the land and wiring pattern.
The reference surface is generated using the wiring
pattern height. So, register an offset value to set the land surface
height to zero.
Adjust Land Size Individually
Select the checkbox to enable the auto adjustment of the land
windows individually when windows are positioned to multiple
components of the same component number for component
registration.
If the checkbox is not selected, the land windows of the same size
as those positioned on the sample component are placed on all
the components with the same component number.
The checkbox is selected by default.
Deselect the checkbox if the land color teaching is difficult as
in e.g. solder leveled PCB teaching.
Quality Criteria
Select the criteria rule book to use in the pull-down menu.
By default, one of the following two can be selected:
Default Level1-Ver200E: Preference for direct pass rate
Default Level2-Ver200E: Preference for fault detection
Refer to P3-4 "3.3 Configuring Quality Criteria Setting" for the details
and editing method on criteria rule books.
Comment
Enter comments such as supplemental information regarding the
inspection program within 256 characters. (This is not
case-sensitive.)
Alphanumerical characters and symbols can be used.
Chapter 2 Inspection Programming
2-32
4.
The following dialog appears. Capture the bare board and good
inspection PCB images with the PCB inspection system.
Refer to the Operation Manual of the inspection machine, Chapter 3:
Capturing PCB Image" for the procedure to capture a PCB image.
Click [Close]. The dialog closes and the Select PCB screen returns.