Omron V-TS Teaching Manual.pdf.pdf - 第44页

2.1 Bas ics of Teaching 2- 17 2.1.3 Image Di splay Area Operation  Move Field of Vision <For Small Movem ent> 1. Click (Move Fie ld of Vision) butt on in the Image Oper ation tool bar. The m ouse cursor changes t …

100%1 / 350
Chapter 2 Inspection Programming
2-16
Target Image List
For the component of the thumbnail image displayed in the image display area, height
calculation, re-learning, and so on are performed.
For the details of the method to operate the image on the target image list, refer to 2.5
Registering the Component Number Model.
(6) Display Switch Tabs
Display switch tabs are provided. They are positioned in the order of the depth of teaching
progress (from left to right).
The following shows the operation available with each tab.
Tab
Outline of Operation
Load the mounting data and register the components to inspect.
Specify the inspection windows (component body, land and
electrode windows) by the unit of component number.
Select a component thumbnail for the component number, based on
which a model is calculated. The characteristic parameters for the
component number is then automatically extracted, and the model is
registered in the library.
Set the criteria values for each of the inspection items for the
component number.
Edit a component number model image registered in the library.
Specify the criteria values for each of inspection items for individual
components.
Perform Component Block Unit settings (position change, copy or
deletion) and mark settings (2D code).
Inspection images and adjustment images are read in, the PCB is
tested, and the result is listed.
Load mass-production images specified by Q-upNavi and images
judged as inspection NG by v-TS, select an image to register it in
the library. In addition, images checked on the [Save Image] column
are also included in the mass-production images regardless of the
inspection result.
式変更: フォント : 10 pt
削除: Registering the Component Number
Model
2.1 Basics of Teaching
2-17
2.1.3 Image Display Area Operation
Move Field of Vision
<For Small Movement>
1.
Click (Move Field of Vision) button in the Image Operation
tool bar. The mouse cursor changes to .
2.
Drag and drop the PCB image to change the field of vision.
Drag and drop using the right mouse button, instead of using the image operation button, can also
move the field of vision.
<For Large Movement>
1.
Click (PCB Map) button in the Image Operation tool bar to
display the PCB map.
2.
Locate the mouse cursor on the field of vision window in the PCB
map (intersection of the yellow lines). The mouse cursor changes
from to .
3.
Drag the field of vision window in the PCB map.
4.
Drop the window at a desired location in the PCB map to position
the field of vision.
Operation
Chapter 2 Inspection Programming
2-18
Change Magnification Ratio
<Magnify/Reduce>
The image can be enlarged or reduced in the following three ways:
1) Click (Magnify) button or (Reduce) button in the Image Operation tool bar.
2) Move the slide bar up or down in the Image Operation tool bar.
Move it upward to magnify, and downward to reduce.
3) Position the mouse cursor on the image display area and rotate the mouse wheel.
Rotate it upward to magnify, and downward to reduce.
The magnification ratio changes by one step increment as shown below:
Maximum reduction ratio
x0.01 -> ->
-> x0.25 -> x0.50 ->
×
1.00 -> x2.00 ->
-> x4.00
<Original Size Display>
1.
Click (Original Size) button in the Image Operation tool bar.
The software displays one pixel of the camera image in the same
size (100%) as one pixel of the image display area.
<Entire PCB Display>
1.
Click (Entire View) button in the Image Operation tool bar.
The entire PCB view is displayed.
Operation
Operation