Omron V-TS Teaching Manual.pdf.pdf - 第40页
2.1 Bas ics of Teaching 2- 13 <Name> Name Description Component Num ber Group A group of c omponent n umbers . In a component number group, windows, inspection crit eria, and characterist ic parameters are s hared.…

Chapter 2 Inspection Programming
2-12
Display Magnification Buttons
Button
Function
Operation
Magnify
Magnifies the image display area by one step increment.
(Max. ratio: 10.0 times)
Reduce
Reduces the image display area by one step increment.
(Min. ratio: 0.01 times)
Magnify/Reduce
The slider to magnify or reduce the image display area.
Slide up the slider to magnify, and down to reduce.
Original Size
Displays the image in the display area at the same magnification of
pixels.
Entire View
Displays the entire image of the PCB in the display area.
Display Switch Buttons (Only effective on screens where thumbnails can be displayed)
Button
Function
Operation
PCB Display
Only displays the PCB image in the image display area.
Clicking this button again brings back the default display (PCB
image and component thumbnail images).
Component
Thumbnail
Display
Clicking the button displays the component thumbnails in the image
display area.
Clicking this button again brings back the default display (PCB
image and component thumbnail images).
Auxiliary Tool Buttons
Button
Function
Operation
Window
Adjustment
Dialog
Displays the window adjustment dialog.
The dialog provides the adjustment of window position and size with
buttons.
Used when fine adjustment with the mouse is difficult.
PCB Map
Displays the PCB map.
Shows the current field of vision of the image display area on the
PCB map in the form of a window. The field of vision can be moved
by drag and drop of the window.
(5) Information Display Area
Editing operation can be proceeded while checking the information of individual components
such as the component number list and inspection criteria.
■ Component Number List
The following shows the operation procedures of the Component Number List.
The Component Number List comprises the Component Setting, Component Registration
(Auto) and Criteria Setting (Product No.) screens.

2.1 Basics of Teaching
2-13
<Name>
Name
Description
Component Number
Group
A group of component numbers. In a component number group,
windows, inspection criteria, and characteristic parameters are shared.
Component No.
Refer to 2.1.1 “Basic Knowledge of Teaching.”
Component Type
Refer to 2.1.1 “Basic Knowledge of Teaching.”
Component Size
Size of the component body window
Judgment
Judgment result when the PCB test is performed
No. of components
No. of components on the PCB
No. of electrodes
No. of electrodes of the component
Description
Text to explain the characteristics of the component number is kept.
Double click the exlanation of component number. The [Explanation Entry] dialog box is
displayed.
Text can be entered by clicking the text box.
[OK]: When clicked, the edited content is applied and the dialog box is closed.
[Cancel]: When clicked, the edited content is dicarded and the dialog box is closed.
[Apply]: When clicked, the edited content is applied and the dialog box is kept open.
With the [Description Entry] dialog box open, the selected component number can be
switched on the component number list.
<Component Number Lock>
To avoid data loss due to simultaneous update of component numbers, the software performs
exclusive control using the component number lock function.
The buttons shown in the row represent the lock status of individual component numbers.
・ … Not locked. Read only. Editing is disabled.
When you click the button, it changes to and editing is enabled.
・ … Locked. Editing is enabled but other users cannot edit.
When you click the button, the lock will be released and the button changes to .
・ … Locked by other user (Locked).
Editing is disabled until another user releases the lock.
When you click [Lock All], the component numbers of become at once.
When the component number information is not up to date, is displaied and the update
check is performed by clicking .
To update the component number to the latest one, click [Update].

Chapter 2 Inspection Programming
2-14
When you select [Do Not Update], the corresponding component number cannot be edited.
If an application program is shut down forcibly, it might occur that the lock state is not released
correctly and component numbers cannot be edited. In this case, select [Tool] – [Forced Lock
Release] on the menu bar, and select a lock release target to release the lock.
<Progress Signal>
The lighting status of the three signal bars shown in row in the Component Number List
represents the teaching status of individual product numbers.
The component numbers for oblique inspection are displayed in a different background color.
The left signal bar lights up in red if the oblique image is not captured yet.
Oblique
Inspection
Product Number Teaching Progress
No
Yes
The component number information is not specified yet
A sample component for the component number has been registered
All component windows have been automatically adjusted
All component windows have been automatically adjusted, the model
has been registered, and component and electrode heights have been
configured
The model has been registered, but the windows are not automatically
adjusted yet
(The number of electrodes of the component number has changed, or
the number of electrodes of the component number does not match the
number of lands because the process to add or delete a land is on the
way.
<Auto Adjustment>
Use the [Adjust] button at the bottom of the Component Number List to automatically adjust
the windows.
The [Automatic Adjustment] button is enabled only when the component number lock is locked
( -> ).
The [Adjust] button is available on the Component Registration screen and Criteria
Setting (Product No.) screen.