Omron V-TS Teaching Manual.pdf.pdf - 第230页

2.16 M anaging PC B Im ages 2- 203 ■ P osition Correction M odel Editing T ool: Explanation of Screen Functions This section exp lains various f unctions displayed on t he right side of the Referen ce Level Model Editing…

100%1 / 350
Chapter 2 Inspection Programming
2-202
2.16.5 Editing a Position Correction Model
When conducting inspection on the machine or testing PCBs using v-TS, if the land extraction
position is different from that of the actual PCB, edit the position correction model using the
position correction model editing tool. This section describes the operation procedure of this tool.
1.
On the menu bar of the editing screen, select [Tool] - [PCB Screen
Management Screen]. If a raw PCB screen is displayed, select
Inspection PCB from the list.
2.
On the PCB screen list, click the inspection PCB image edited
(PCB type: adjustment image) to select it to a master. Then, click
[Edit Reference Level Model] to start up the reference level model.
3.
Edit the position correction model.
The editing method using the position correction model
editing tool is described on and after the next page.
2.16 Managing PCB Images
2-203
Position Correction Model Editing Tool: Explanation of Screen Functions
This section explains various functions displayed on the right side of the Reference Level
Model Editing Tool .
Selection Button: Use when selecting a land on the screen. For the selected land, position
and size can be edited.
It is unable to move the position and size of the land out of the
inspection range window.
Pen Tool: When a pixel extracted on the PCB surface is clicked, the color of the pixel is
added to the color table. Pen’s thickness can be specified with the slide bar.
Pen's thickness can be specified in a range of one to 21 pixels.
Eraser Tool: When the extracted pixel on the PCB surface (cyan color portion) is clicked,
the color of the pixel is deleted from the color table. Eraser’s thickness can be specified with
the slide bar.
Erasers thickness can be specified in a range of one to 21 pixels.
Extension Range Setup Tool: Specify the extension range of the color of the pixel selected
by the pen/eraser tool with the slide bar.
The extension range can be specified in a range of 0-20.
Clear Button: All color settings are deleted from the color table.
Undo Button: Edited content of the color table can be cancelled.
Chapter 2 Inspection Programming
2-204
Overlay Switch: The extracted pixels on the PCB surface (cyan color portion) are
displayed.
Display Magnification Slider: Enables to change the magnification of display.
Capture List: The visual field of the inspection program is displayed.
Edit Color Switch: A color table to adjust the land position automatically can be displayed/
edited.
Adjust Button: The position of the selected land window is adjusted automatically.
All Adjust Button: The positions of all the land windows are adjusted automatically.
Destination Button: If destinations are set, the destinations edited can be changed.
Component List: Component numbers, circuit numbers, component block unit numbers,
and affiliated inspection visual field numbers are displayed. When a line is selected, control
is moved to the component and a window is displayed.
Type: The reference of the position correction model can be changed.
If post-mounting inspection is conducted and it is detected that
solder paste extends beyond the land, or if a lot of bottom
electrode components such as BGA are implemented and the
land is not visible, select [Wiring Pattern].
Close Button: The position correction model which has been edited completely is saved.