MR8740、MR8741_user_manual_eng_20191016H.pdf - 第200页

7.11 Saving Waveforms Registered in Model U8793 onto a Storage Device 188 You can save the arbitrary waveform data r egistered in U8793 in the media. For saving methods, re fer to "4.2.5 Save Waveform Output Data to…

100%1 / 428
7.10 Register the Waveform in the U8793 Arbitrary Waveform Generator Unit
187
6
Chapter 7 Utility Functions
7
5
Set the conversion ratio.
6
Enter a data name.
Register as an arbitrary waveform data in the U8793 memory.
Enter a [Name].
When a data name is not entered, the data will be registered as [NONAME].
Amplify or attenuate a voltage value of the measured data to register it.
0.001 times to 100 times
7.11 Saving Waveforms Registered in Model U8793 onto a Storage Device
188
You can save the arbitrary waveform data registered in U8793 in the media.
For saving methods, refer to "4.2.5 Save Waveform Output Data to the Media" (p.98).
Parameters (frequency, amplitude, and offset) for the output waveform that was configured on the Generator
screen (signal generation setting screen) can be changed on the Waveform screen.
The ability to configure and change these settings while outputting and measuring the resulting waveform pro-
vides a convenient way to measure a waveform while varying its parameters.
7.11 Saving Waveforms Registered in Model
U8793 onto a Storage Device
7.12 Setting Output Waveform Parameters on the
Waveform Screen
1
Display the Waveform screen (if viewing another screen, press DISP to display the Waveform
screen).
2
Press CH.SET (to display the tabs).
3
Press CH.SET or select the [Generator] tab with the mouse.
4
Set the following parameters as desired.
3
4
Select
Selections Description
Frequency Sets the frequency.
Amp Sets the amplitude.
Offset Sets the offset.
Output Turns output on or off.
For details, see the instruction manual of Models U8793, MR8790, and MR8791.
189
7
Chapter 8 Trigger Settings
8
Triggering is the process of controlling the start and stop of recording by specific signals or condi-
tions (criteria). When recording is started or stopped by a specific signal, we say the trigger is
"applied" or "triggering occurs".
Trigger settings are made in the Trigger settings window of the Waveform screen.
Trigger Settings Chapter 8
Opening theTrigger settings window
Click [TRIG.SET] in the right-
click menu.
If the trigger setting screen is hard to see due to waveform overlap, narrow the wave-
form display width to divide the waveform display screen and trigger settings screen.
Refer to "6.7.3 Switching the Waveform Display Width" (p.135).
Trigger Settings
Trigger mode setting (p.191)
Combining logic (AND/OR) for multiple trigger
sources (p.208)
Pre-trigger settings (p.204)
Analog Trigger Settings (p.192)
Level trigger
Window trigger
Period trigger
Glitch trigger
Slope trigger
Logic Trigger Settings (p.197)
Setting combining logic for logic triggers
Trigger filter settings
Trigger pattern settings
Manual Trigger Settings (p.203)
Trigger Source Settings
Trigger Output (MR8741) (p.341)
Operations available from the Trigger settings window
External Trigger Settings (p.203)
Timer Trigger Settings (p.199)
Searching for trigger positions (p.209)