KJ-01.02.Instruction Manual.REV.02.pdf - 第156页
5 − 60 ⑥ Nozzle No. W hen you enter the component dimensions, the machine aut omatically sets the nozzle number . If you want to change t his nozzle number because the machine is not eq uipped with the nozzle w hose numb…

5 − 59
• One-way lead connector
• Two-way lead connector
• Z style lead connector

5 − 60
⑥ Nozzle No.
When you enter the component dimensions, the machine automatically sets
the nozzle number. If you want to change this nozzle number because the
machine is not equipped with the nozzle whose number is automatically set,
select an appropriate one from the displayed pop-up menu, or click the
[2/Edit] command and enter one on the displayed menu. When you enter a
nozzle number from the “Edit” menu, you can select a nozzle that is set with
the [Nozzle data installation] command on the Machine setup menu (see
Section 4.3.10 “Nozzle data installation”).
Figure 5.5.1.10 Nozzle no. input screen
⑦ Vacuum level
The vacuum value, when the component is picked with the nozzle
designated by the nozzle number, is displayed. It is not necessary to change
the value.

5 − 61
<2> Working on the “Tape” window
① Tape width
Select the appropriate tape width from the pop-up menu.
Figure 5.5.1.11 Tape width selection screen
② Feed pitch
Select the feed pitch from the pop-up menu.
Each tape width has unique feed pitches to be selected. Note that certain
feed pitches are not selectable for particular tape widths.
Figure 5.5.1.12 Feed pitch selection screen