KJ-01.02.Instruction Manual.REV.02.pdf - 第407页
11 On Production Control Operations Error No. Error Message Correctiv e Action E5000 Numeric value input area error . The value y ou try to set on the Production conditions menu exceeds the allow able setting range. Chec…

10
On I/O Manual Operations
Error No. Error Message Corrective Action
W4200 Z position limit over. The entered Z-axis coordinate exceeds the allowable setting
range. Check the allowable range to enter the coordinate
again.
W4231 Can't use bad mark sensor.
Please check 'Installed options
' of SETUP.
Although the check box “BAD mark sensor” is not checked
on the “Use unit” menu invoked from the Setup menu, you try
to operate the bad mark device to perform teaching
operation. Check the settings of the “Use unit” menu with
invoking it from the Setup menu.
W4232 Can't use BOC. Please check '
Installed options
'
of SETUP.
Although the check box “BOC camera” is not checked on the
“Use unit” menu invoked from the Setup menu, you try to
operate the camera device to perform teaching operation.
Check the settings of the “Use unit” menu with invoking it
from the Setup menu.
W4240 Can't use PWB conveyer.
Please check 'Installed options
' of SETUP.
Although the check box “Conveyor connect” is not checked
on the “Use unit” menu invoked from the Setup menu, you try
to operate the automatic board conveyor. Check the
settings of the “Use unit” menu with invoking it from the
Setup menu.

11
On Production Control Operations
Error No. Error Message Corrective Action
E5000 Numeric value input area error.
The value you try to set on the Production conditions menu
exceeds the allowable setting range. Check the allowable
setting range to set it again.
W5010 PWB data not complete yet.
You tried to use a production program whose PWB data is not
created completely to produce PWBs. Only after creating a
production program with the Data Input command, start PWB
production.
W5011 Placement data not complete yet.
You tried to use a production program whose Placement data
is not created completely to produce PWBs. Only after
creating a production program with the Data Input command,
start PWB production.
W5012 Component data not complete yet.
You tried to use a production program whose Component
data is not created completely to produce PWBs. Only after
creating a production program with the Data Input command,
start PWB production.
W5013 Pick position not complete yet.
You tried to use a production program whose Pick data is not
created completely to produce PWBs. Only after creating a
production program with the Data Input command, start PWB
production.
W5014 Mark data not complete yet.
You tried to use a production program whose mark data is not
created completely to produce PWBs. Only after creating a
production program with the Program Editor, start PWB
production.
W5020 Conveyer reference data unmatch
MS parameter's and PWB data's.
You tried to use a production program created with a machine
whose PWB transport reference is different from this machine
in order to start PWB production.
W5021 Conveyer direction data unmatch
MS parameter's and PWB data's.
You tried to use a production program created with a machine
whose PWB transport direction is different from this machine
in order to start PWB production.
W5022 Shape reference has been
selected in PWB data, but shape
reference unit is not connected to
the machine.
You tried to produce PWBs with using a production program
that uses a shape clamp device although the machine is not
equipped with a shape clamp device or a sh Check the data
with the Data Input command to retry PWB production.ape
clamp device is not set on the Setup menu.
E5023 Planned num. is less than
produced num.
Although you check the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu invoked from the
“Production” menu, you try to set the number that is equal to
the number of PWBs already produced or less as the planned
number of PWBs to be produced.
Set the larger number as the planned number, or clear the
production management information before starting
production.
Or, uncheck the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu.
E5024 Total placement points are within
10,000.
The total number of component placement points per
multiple-plane board is limited to 10000. Decrease the
number of placement points of a circuit or decrease the
number of circuits until total number of placement points
becomes 10000 or less before starting PWB production.
E5025 Don't exist program.
You tried to start PWB production although you had never
loaded any production program into the machine. Only alter
loading a production program into the machine, start PWB
production.
E5026 Integrated PWB number have
reached production plan.
Although you check the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu invoked from the
“Production” menu, you try to produce PWBs with setting the
number of PWBs already produced larger than the planned
number of PWBs to be produced.
Increase the planned number of PWBs to be produced, or
clear the production management information before starting
PWB production.
Or, uncheck the check box “Integrate num. Of PWBs
produced.” on the “Operation option” menu.

12
E5030 Limit over.(BOC mark points.) You tried to start PWB production with using a production
program that specified the BOC mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.
E5031 Limit over.(Placement points.) You tried to start PWB production with using a production
program that specified the component placement coordinates
out of the area components can be placed.
Check the data with the Data Input command to retry
production.
E5032 Limit over.(IC mark points.) You tried to start PWB production with using a production
program that specified the IC mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.
E5033 Limit over.(BAD mark points.) You tried to start PWB production with using a production
program that specified the bad mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.