KJ-01.02.Instruction Manual.REV.02.pdf - 第180页
5 − 84 5.6.4 Stick feeder specifications - The stick f eeder type and the hole positions occupied t o install a stick f eeder T able 5.6.4.1 Stick feeder type Number of the hole position occupied to install a stick feede…

5 − 83
(3) Type
Select a bulk feeder type.
Figure 5.6.3.3 Inputting a bulk feeder type
Since a tape feeder type should be entered on the Component data, you cannot
select any type.
(4) X1, Y1, Z
These parameters set the coordinates of the feeder pick position. They are
automatically calculated and shown after “Side” and “No” items have been defined.
Fine-adjustments are possible by teaching.
(5) Use
The default setting “Yes” (use) appears. To change the setting, press the Edit key
(F2) to open a pop-up menu and select “No”.
Figure 5.6.3.3 Use setting screen
Descriptions of “Use” settings
Setting Description
1/Yes For production, components from this feeder are used in production.
2/No For production, components are not picked up from this feeder in
production.

5 − 84
5.6.4 Stick feeder specifications
- The stick feeder type and the hole positions occupied to install a stick feeder
Table 5.6.4.1
Stick feeder type Number of the hole position
occupied to install a stick feeder
TYPE-N 3
TYPE-W 6
(1) Type
The type of the stick feeder is selected from the pop-up menu.
Figure 5.6.4.1 Stick feeder “Type” setting screen
(2) Side (Supply)
The same as the tape.
(3) No (Position)
This parameter sets the feeder mounting hole number into which the stick feeder
positioning pin is inserted.
When a number is changed, the parameters to the right of “No” are initialized.
As soon as a number is entered, overlap is checked for the existing tape feeders
and tray holders. If the same number already exists, the entry is rejected with an
error message shown on the screen.
(4) Angle
Set the angle for supplying a component.
The item “Angle” indicates the component supply angle based on the placement
angle, 0 degrees.
Since a tape component supply direction should be specified on the Component
data screen, you cannot specify its supply angle. The anti-clockwise direction is
supposed to be positive.
(5) X1, Y1, Z
These parameters set the coordinates of the feeder suction position. When
“Sply”, “Pos.”, “Type”, and “Lane” are set, these values are automatically
calculated and shown.
Fine-adjustments are possible by teaching.
(6) Use
The same as the tape.

5 − 85
5.6.5 Tray component data entry
(1) Type
Since only a tray holder can be installed on the machine, you cannot select its
type.
(2) Side and No
Since a tray holder is fixed on the rear side, you cannot enter any type or
number.
(3) Angle
See the description of a tape feeder also.
When you enter a value to this item, the machine checks to see if the position of
a tray holder is not overlapped with another device: the already set tape feeder,
stick feeder and/or bulk feeder. If it is overlapped, an error message appears
on the screen, and the machine rejects your setting of the item “Angle.”
− Placement angle 0°
QFP QFP (PLCC) SOP TSOP-1 TSOP-2 Connector
Figure 5.6.5.1 Placement angle
0
00
0°
°°
°
− Setting example of supply angle
Figure 5.6.5.2 Supply angle of components
Tray holder
QFP
0°
Stick feeder
QFP
0°
SOP
270°
SOP
0°
SOP
90°
SOP
270°
QFJ
0°
QFJ
90°
Figure of stick feeder
at the front side of the machine
: Direction of the view which
is used for determining the
"Supply angle"