5 − 62 ③ Dir ection (Component feed dir ection) Def ine the angle of component feed accor ding to t he lot of the component s. The angle f or the usually fed component s shall be set to 0 deg ree. For the other component…

100%1 / 419
5 61
<2> Working on the “Tape” window
Tape width
Select the appropriate tape width from the pop-up menu.
Figure 5.5.1.11 Tape width selection screen
Feed pitch
Select the feed pitch from the pop-up menu.
Each tape width has unique feed pitches to be selected. Note that certain
feed pitches are not selectable for particular tape widths.
Figure 5.5.1.12 Feed pitch selection screen
5 62
Direction (Component feed direction)
Define the angle of component feed according to the lot of the components.
The angle for the usually fed components shall be set to 0 degree. For the
other components with different angles, change only the feed angle.
Placement angle is not necessary to change.
Figure 5.5.1.13 Component feed direction selection screen
When selecting [5/ Other], a pop-up menu for entering placement angle appears.
Enter the desired angle within the range of to 359°.
This feature can be used for the components fed at an angle of 45° such as
GaAsFET.
Direction input dialog box
5 63
<3> Working on the “Tray” window
The window for tray setting is shown in Figure 5.5.1.14.
Figure 5.5.1.14 Tray setting dialog box
First pos. (position)
Enter the center position (X and Y) of the first component on the tray,
measured from the edge of the tray.
Pitch
Enter the pitches (pitches X and Y) between components.
No. of row and line (number of components)
Enter the number of components (Xn, Yn) in horizontal and vertical
directions.
Figure 5.5.1.15 Figure of First component position, pitch,
and the number of components
Yn
Xn
Tray holder
Pitch Y
First component position
Board Transport path