8 E2660 Enter angle ranges is between 0(deg.)|and 359(deg.). Y ou can set the component supply direction within the range from 0 to 359 degrees only . Set the direction so that it can be within this range. E2661 T ray da…

7
E2301 This is placed component. Can not
delete.
You cannot delete any component data record that is referred
from Placement data on the Component data list screen. To
delete such a component data record, first delete all of the
data lines that refer to the component data record on the
Placement data screen.
E2302 Component name is duplicated. The component name you specified to rename to already
exists. If you want to change the component name to this
name, change the existing component name to another one
first.
E2303 No component data to copy. Unless a Component data record is entered completely, it
cannot be copied. This error message appears on the
screen if you try to copy data although there is no completed
Component data.
E2304 Component name'****'can't be
found.
This error message appears on the screen if there is not a
component whose name is specified from the edit box
directly to specify the copy source component data. The list
box shows components whose data is completely entered.
See this box to specify the copy source component name.
E2500 Component data is not finished
yet.
You tried to edit Pick data although there is no completed
Component data. Only after creating at least one
component data line, edit Pick data.
E2501 Value is out of range. This error message appears on the screen if the component
pick-up coordinate automatically calculated exceeds the
machine X- and Y-direction movable range. Especially for a
tray holder, check to see if the pitch and number components
are entered correctly on the Component data screen.
E2502 Tray holder excessive registration. Up to five trays can be set for one tray holder unit. You
cannot specify any number exceeding this limit.
E2505 Package is already assigned. This error message appears on the screen when another
feeder is already installed on the position you specified.
Check the installation position.
E2507 Pick position data is full. The maximum number of Pick data records is 40 (when two
feeders are installed on the front and rear sides respectively).
(This maximum number varies depending on the unit you
use.)
You cannot copy any data if the copy operation generates
data records that exceed this limit.
E2509 No data for feeder order display. This error message appears if you try to display the Pick data
in the component pick-up order although you have not
created any Pick data completely. Create at least one Pick
data record.
E2511 Not found component name. **** The component name “*****” you specified to search through
Pick data on the Edit screen does not exist.
E2516 Unable to select rear side. A 32-mm paper tape feeder cannot be installed on the rear
feeder bank. Install it on the front bank.
E2603 Entry name is already registered. This error message appears on the screen if you try to
register mark data that is already registered to the mark
database.
E2652 The IC conveyer belt competes
with the feeder.
This error message appears on the screen if the component
pick-up position from the IC recovery belt and that from a
feeder are overlapped with one another at start of production.
Set the component pick-up position from the feeder so that it
cannot be overlapped with that from the IC recovery belt.
E2653 IC conveyer belt is assigned. This error message appears on the screen if the component
pick-up position from the IC recovery belt and that from a
feeder are overlapped with one another when you set the
component pick-up position.
Set the component pick-up position from the feeder so that it
cannot be overlapped with that from the IC recovery belt.

8
E2660 Enter angle ranges is between
0(deg.)|and 359(deg.).
You can set the component supply direction within the range
from 0 to 359 degrees only. Set the direction so that it can
be within this range.
E2661 Tray data is max. Cannot be used. Up to five trays can be set for one tray holder unit. You
cannot specify any number exceeding this limit.
E2305 Component name'****'is
incompleted.
On the Component data edit screen, you can copy a
component whose data is completely entered. Before
copying data, create Component data completely.

9
On Setting Up
Error No. Error Message Corrective Action
E4101 Illegal charactor or format error. This error message appears when you enter an alphabetic
character for the item for which a numeric character should
be entered.
E4102 Limit over You entered data that exceeded the range regulated for the
item. Check the regulated data entry range to enter
appropriate data.
E4122 Select error. (Select conveyer
connect or turn conveyer)
You tried to check the check boxes “Conveyor connect” and
“Turn conveyor” on the “Use unit” menu.
You can check either of these check boxes.
E4126 Shape reference can't be used. This error message appears on the screen if you check the
check box “Shape clamp” on the “Use unit” menu although
the machine is not equipped with a shape clamp unit. You
cannot use a shape clamp unit.
E4127 BAD mark sensor is not install. This error message appears on the screen if you check the
check box “BAD mark sensor” although the machine is not
equipped with a bad mark sensor. You cannot use a bad
mark sensor.
E4128 Front feeder rise sensor is not
install.
This error message appears on the screen if you check the
check box “Front fdr. Float detector” on the “Use unit” menu
although the machine is not equipped with a feeder float
detector on its front. You cannot use a feeder float detector
(on the front side
E4129 Rear feeder rise sensor is not
install.
This error message appears on the screen if you check the
check box “Rear fdr. Float detector” on the “Use unit” menu
although the machine is not equipped with a feeder float
detector on its rear. You cannot use a feeder float detector
(on the rear side).