KJ-01.02.Instruction Manual.REV.02.pdf - 第408页

12 E5030 Limit over .(BOC mark points.) Y ou tried to start PW B production with using a production program that specified the BOC mark coordinates out of the area components can be placed. Check the data with the D ata …

100%1 / 419
11
On Production Control Operations
Error No. Error Message Corrective Action
E5000 Numeric value input area error.
The value you try to set on the Production conditions menu
exceeds the allowable setting range. Check the allowable
setting range to set it again.
W5010 PWB data not complete yet.
You tried to use a production program whose PWB data is not
created completely to produce PWBs. Only after creating a
production program with the Data Input command, start PWB
production.
W5011 Placement data not complete yet.
You tried to use a production program whose Placement data
is not created completely to produce PWBs. Only after
creating a production program with the Data Input command,
start PWB production.
W5012 Component data not complete yet.
You tried to use a production program whose Component
data is not created completely to produce PWBs. Only after
creating a production program with the Data Input command,
start PWB production.
W5013 Pick position not complete yet.
You tried to use a production program whose Pick data is not
created completely to produce PWBs. Only after creating a
production program with the Data Input command, start PWB
production.
W5014 Mark data not complete yet.
You tried to use a production program whose mark data is not
created completely to produce PWBs. Only after creating a
production program with the Program Editor, start PWB
production.
W5020 Conveyer reference data unmatch
MS parameter's and PWB data's.
You tried to use a production program created with a machine
whose PWB transport reference is different from this machine
in order to start PWB production.
W5021 Conveyer direction data unmatch
MS parameter's and PWB data's.
You tried to use a production program created with a machine
whose PWB transport direction is different from this machine
in order to start PWB production.
W5022 Shape reference has been
selected in PWB data, but shape
reference unit is not connected to
the machine.
You tried to produce PWBs with using a production program
that uses a shape clamp device although the machine is not
equipped with a shape clamp device or a sh Check the data
with the Data Input command to retry PWB production.ape
clamp device is not set on the Setup menu.
E5023 Planned num. is less than
produced num.
Although you check the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu invoked from the
“Production” menu, you try to set the number that is equal to
the number of PWBs already produced or less as the planned
number of PWBs to be produced.
Set the larger number as the planned number, or clear the
production management information before starting
production.
Or, uncheck the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu.
E5024 Total placement points are within
10,000.
The total number of component placement points per
multiple-plane board is limited to 10000. Decrease the
number of placement points of a circuit or decrease the
number of circuits until total number of placement points
becomes 10000 or less before starting PWB production.
E5025 Don't exist program.
You tried to start PWB production although you had never
loaded any production program into the machine. Only alter
loading a production program into the machine, start PWB
production.
E5026 Integrated PWB number have
reached production plan.
Although you check the check box “Integrate num. of PWBs
produced.” on the “Operation option” menu invoked from the
“Production” menu, you try to produce PWBs with setting the
number of PWBs already produced larger than the planned
number of PWBs to be produced.
Increase the planned number of PWBs to be produced, or
clear the production management information before starting
PWB production.
Or, uncheck the check box “Integrate num. Of PWBs
produced.” on the “Operation option” menu.
12
E5030 Limit over.(BOC mark points.) You tried to start PWB production with using a production
program that specified the BOC mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.
E5031 Limit over.(Placement points.) You tried to start PWB production with using a production
program that specified the component placement coordinates
out of the area components can be placed.
Check the data with the Data Input command to retry
production.
E5032 Limit over.(IC mark points.) You tried to start PWB production with using a production
program that specified the IC mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.
E5033 Limit over.(BAD mark points.) You tried to start PWB production with using a production
program that specified the bad mark coordinates out of the
area components can be placed.
Check the data with the Data Input command to retry
production.
13
On Production
Error No. Error Message Corrective Action
E5500 System Error !
<ID:## Status:####>
The production operation section of the machine causes a
system error. This error is a fatal system software error.
Let us now the displayed ID and status number:
ID
13 Occurred during tracking with a camera.
0D Occurred during component pick-up/placement
operation.
0E Occurred during component pick-up operation.
11 Occurred during component placement operation.
01 Occurred at the main production operation section.
08 Occurred during bad mark detection.
09 Occurred during BOC mark detection.
0A Occurred during IC mark detection.
E5601 Undefined nozzle (No.***) is used. A production program to be executed specifies a nozzle
number that is not set on the Setup menu.
Check its Component data or Setup data.
E5602 Feeder is empty or has an error. Production is impossible because all of feeders run out
components or enter the error status as the result of the
previous production.
Reset the number of components or clear the error to retry
production.
E5604 BOC mark correction error. An error occurred while the machine was calculating a
correction value based on the BOC mark recognition result.
E5605 IC mark correction error. An error occurred while the machine was calculating a
correction value based on the IC mark recognition result.
E5606 PWB counter error. A contradiction of the number of PWBs occurred at start of
production due to the system internal error.
E5607 Step counter error. A contradiction of the setting of placement step to be
executed occurred at start of production due to the system
internal error.
E5608 There is no executive data. All Placement data records to be executed are skipped or all
Pick data records to be executed are set to “No Use”.
Check Placement data, Pick data, Step No. displayed on the
Production screen, and/or restart position.
E5609 Control index error. A production program specifies the feeder the system does
not handle. Check its Component data or Pick data.
E5660 LA recognized error. Pick retry
over.
The LA measurement failure retry-over error occurs. (The
number of retries is specified on the Component data screen.)
The component pick-up posture may be incorrect or the
component dimensions may be irregular. Check the
component pick-up position.
E5661 Component fall. Retry from pick? The machine could not detect a component when it finally
checked whether there is a component to be picked up: this
check is to be performed immediately before a component is
placed on a board.
A component may be dropped onto a board. Check to see
where a component is located.
E5662 Cannot component placement.
Retry from pick?
After placement, a component is detected with the
component existence check. The component might be
taken away from a board. Check to see where the
component is located.
W5700 Component scrap error (Status:**).
|Remove component from nozzle.
A component remains stuck to a nozzle after component
discarding process. Remove the component from the tip of
the nozzle.
The sensor section of the LA may be spoiled.
E5701 Component exist on the top end of
nozzle. Not remove nozzle.
A component is stuck to the nozzle when the nozzle is
returned to the ATC.
E6200 Vision recognition setting error. An error occurred when the machine was setting the BOC/IC
mark recognition conditions at start of production.