17 E7504 PW B convey er error . (BACKUP sensor) Check air pressure. This error occurs if the support plate up sensor cannot be set to ON even w hen the certain period of time passes after a board is sent into the machine…

16
E7021 Driver error XY pulse out time
over error <%d> Power off.
This error occurs if any interrupt for clearing a pulse is
notified to the machine even when the certain period of time
passes after the XY-axis movement instruction is issued.
Turn off the machine, and then restart it.
If this error occurs again, the XY pulse generation board may
malfunction, or interface with this board may be faulty (due to
faulty connection, a broken wire or IC error). Do not restart
the machine.
E7023 Driver error XY CCL-48M buffer
busy error <**>
This error occurs if the counter CCL-48M used for the
XY-axis remains busy even after a certain period of time
passes.
This error is caused by malfunction of the AC servo driver,
broken of a cable or faulty connector connection. Do not
restart the machine
E7027 Z home sensor has been off
detected. <**> Power off.
This error occurs if the home position sensor is set to OFF
while the machine is finding the home position (motor index
signal) to return the Z-axis to its home position.
The Z-axis home position sensor or motor index signal may
malfunction. Do not restart the machine.
W7340 Front feeder rise sensor has been
detected.
This error occurs when the machine detects a floating feeder
on the front side.
Recover the feeder from the floating error, and retry the
operation
W7341 Rear feeder rise sensor has been
detected.
This error occurs when the machine detects a floating feeder
on the rear side.
Recover the feeder from the floating error, and retry the
operation.
E9340 Front feeder rise sensor has been
detected. Please release the
switch and return to home.
This error occurs if the machine detects a floating feeder on
the front side when the check box “Stop by detected feeder
float” is checked on the Setup menu.
Recover the feeder from the floating error, and return it to the
home position.
E9341 Rear feeder rise sensor has been
detected. Please release the
switch and return to home.
This error occurs if the machine detects a floating feeder on
the front side when the check box “Stop by detected feeder
float” is checked on the Setup menu.
Recover the feeder from the floating error, and return it to the
home position.
E7501 PWB conveyer error. (CENTER
sensor)
This error occurs if the center sensor cannot be set to ON
even when a certain period of time passes after a board is
sent in the machine and the IN sensor is set to ON.
This error may occur because:
− no air is supplied to the machine, or the air pressure does
not reach the regulated level,
− the center sensor malfunctions,
− a board is caught between the IN sensor and center sensor,
− the PWB transport unit belt is broken, or
− the PWB transport motor malfunctions.
− Recover the machine from the error caused by the
corresponding factor described above.
E7502 PWB conveyer error. (OUT
sensor)
This error may occur because:
− the center sensor cannot be set to OFF even when a
certain period of time passes after a board is ejected from
the machine,
− the OUT sensor cannot be set to ON even when a certain
period of time passes after the center sensor is set to OFF,
or
− the OUT sensor cannot be set to OFF even when a certain
period of time passes after the OUT sensor is set to ON.
The following factors may cause the symptoms described
above:
− The center sensor or OUT sensor malfunctions,
− A board is caught somewhere,
− The PWB transport belt is broken, or
− The PWB transport motor malfunctions.

17
E7504 PWB conveyer error. (BACKUP
sensor) Check air pressure.
This error occurs if the support plate up sensor cannot be set
to ON even when the certain period of time passes after a
board is sent into the machine and the center sensor is set to
ON. This error may occur because:
− no air is supplied to the machine or the air pressure does
not reach the regulated level,
− the reference pin catches a board, and is not inserted into
the reference pin hole, or
− the electromagnetic valve malfunctions.
− Recover the machine from the error caused by the
corresponding factor described above.
E7505 PWB conveyer error. Waiting for
PWB. Remove PWB.
This error occurs when a board is located above the OUT
sensor at start of production. Remove the board from the
sensor, and restart production.
E7506 PWB conveyer error. (IN sensor) This error occurs when the certain period of time passes after
a board is sent into the machine and the IN sensor is set to
ON. This error may occur because:
− the IN sensor malfunctions,
− a board is caught with the IN sensor,
− the PWB transport unit belt is broken, or
− the PWB transport motor malfunctions.
− Recover the machine from the error caused by the
corresponding factor described above.
E7507 PWB detected in work area.
Please remove the PWB.
This error occurs if the center sensor is set to ON before a
board is sent in the machine and the IN sensor set to ON.
This error occurs because:
− a board is located between the IN sensor and the center
sensor, or
− the IN sensor or center sensor malfunctions.
− Recover the machine from the error caused by the
corresponding factor described above.

18
On Asynchronous Operations
Error No. Error Message Corrective Action
E9000 ATC slide plate open time out
error. Check air pressure.
This error message appears on the screen if the slide plate
opens (that is, the sensor senses) a long time after the
machine instructs the ATC slide plate to open.
Check to see if a foreign substance is caught with the slide
plate or the ATC nozzle is tilted. Check to see if air is
supplied to the machine normally also.
If you do not find any problem, open/close the ATC slide
plate with the command supplied on the “I/O manual” menu
to check the sensor condition.
E9001 ATC slide plate close time out
error.|Check air pressure.
Perform the corrective action described at the error number
E9000.
E9010 Nozzle set error is detected before
execute head vacuum level is
nozzle on head level.
The machine finds that a nozzle is attached on the head by
checking it with laser before attaching a nozzle according to
the nozzle replacement command. Check to see if a nozzle
is attached on the head. If attached, remove it, and return it
to the ATC.
If this error occurs when any nozzle is not attached on the
head, check to see if the laser system malfunctions.
E9011 Nozzle set error is detected after
execute head vacuum level is
nozzle none level.
The machine finds that a nozzle is attached on the head by
checking it with laser before attaching a nozzle according to
the nozzle replacement command.
If this error occurs when any nozzle is not attached on the
head, check to see if the laser system malfunctions.
E9012 Nozzle set error is detected before
execute control data is nozzle on
head.
This error occurs if you try to attach a nozzle on a head
although a nozzle is already set on a head with the syste
Even though you manually remove a nozzle from a head, the
system does not detect this fact and operates as if a nozzle
is attached on a head.m.
If the nozzle attachment instruction is issued under this
condition, this error message appears on the screen.
E9020 Nozzle remove error is detected
before execute head vacuum level
is nozzle none level.
When you check to see if a nozzle is attached on the head
with laser before removing a nozzle, you find that no nozzle
is attached.
This error message appears on the screen if you try to
remove a nozzle after manually removing it from the head.
If this error occurs although a nozzle is actually attached,
check to see if the laser system malfunctions.
E9021 Nozzle remove error is detected
after execute head vacuum level is
nozzle on head level.
When you check to see if a nozzle is attached on the head
with laser after removing a nozzle, you find that a nozzle is
still attached. If a nozzle is attached still on the head,
manually remove it from the head, and then return it to the
ATC.
If this error occurs although a nozzle is removed normally,
check to see if the laser system malfunctions.
E9025 Air not supplied. When you check the vacuum pressure, it does not reach the
regul Check to see if the air system malfunctions.ated level.
E9035 Battery for SRAM is dead ! Replace the battery for backing up the system with new one
at the earlier date. If you leave the battery without
replacing, data stored in the RAM disk (drive F) will be lost.
W9100 Selected device can not move to
this position. Please reselect other
device on HOD.
This error message appears if the device selected for
teaching exceeds the XY-direction movable range when it
moves to the specified coordinates.
Use the device that can move over the limited range to
perform teaching operation, or change the destination
position. This error may be caused with some devices also
if the offset specified on the Setup menu is not correct.
Check the offset specified on the Setup menu.