5 − 102 (2) Pick posit ion ① X , Y , and Z coordinates: The coor dinates of the curr ent pick posit ion Manual input and teaching are possible. Not e: These coordinates are not st ored to Pick dat a. ② St ored as the “Pi…

100%1 / 419
5 101
5.7.2.2 Measurement conditions setting
A screen as shown below appears when “Single Measurement” is selected on the
menu.
Component data measurement screen
(1) Execute position
Explanation of measurement screen
Pick position #-##
Supplied
with
##
Tape
Bulk
Stick
Front side
Rear side
Hole number
Holder
Rear side
**
Hole number
Component number
Component package
Pick position
Front side F
Rear side R
Component type
Component name
5 102
(2) Pick position
X, Y, and Z coordinates:
The coordinates of the current pick position
Manual input and teaching are possible.
Note: These coordinates are not stored to Pick data.
Stored as the “Pick data”
If “Stored as Pick data” is checked, the pick position can be stored as the
Pick data.
Note: The components fed with a tray cannot be stored as the Pick data.
(3) Measurement items
Vac. level of comp. pick (Vacuum level of component picking):
Measures the vacuum pressure used for picking up a component.
Height:
Measures the component height.
Outline:
Measures the dimensions of the component package.
Lead info.:
Measures the component lead information.
See “5.10.1.2 Functions” for what to be measured.
Notes:
No measurement is possible if the “Component data” or “Pick
data” is incomplete.
The measurement result is displayed on the Measurement
result screen.
If a component pick error, or laser or VCS recognition error
occurs, the error type is displayed without measurement result.
(4) Operation buttons
Measurement button (F10 key):
Performs the selected measurement.
OK button:
Makes the stored data valid, then exits the screen.
Cancel button:
Makes the stored data invalid, then exits the screen.
Feed button (F4 key):
Feeds a component with a feeder other than a 32 mm paper feeders.
Every time you press the button, the feeder feeds a component.
5 103
5.7.2.3 Execution of single measurement
A screen shown below appears during measurement.
Executing measurement screen
5.10.2.4 Storing the measurement result
When measurement is complete, the following measurement results are displayed.
The displayed results are to be stored as “Component data”. When selecting the
OK button, the data displayed are stored as each data. When selecting the Cancel
button, no data are stored.
Measurement result obtained if you have not selected “Lead info.”
Measurement result obtained if you have not selected “Lead info.” screen