10 − 17 CA UTION The specified nozzle start s being replaced immediately after you click the <CHANGE> button. T o avoid risk of injury , do not place your hand in t he machine, nor move your face or head close to t…

100%1 / 419
10 16
10.4.6 Others
10.4.6.1 ATC control
When you select the [6/Others] command on the menu bar, and then the [1/ATC
control] command on the displayed menu, the dialog box for controlling the ATC
appears on the screen as shown in Figure 10.4.6.1.1.
Each command is described on Table 10.4.6.1.1.
Figure 10.4.6.1.1 “ATC control” dialog box
Table 10.4.6.1.1 Description of each command.
No. Command Description
1 Slide plate control Controls the slide plate (OPEN/CLOSE).
2 Nozzle change Replaces the current nozzle with the nozzle you specified.
3 Status Displays the condition of the slide plate and the number of a nozzle located
at each ATC position.
When you select a button displayed on the dialog box above, the specified control
operation starts. The controlled condition is displayed in real time.
When you click the <CHANGE> button on the “Nozzle change” window, a nozzle
whose position: A to D is checked is replaced with another one.
10 17
CAUTION
The specified nozzle starts being replaced immediately after you click
the <CHANGE> button.
To avoid risk of injury, do not place your hand in the machine, nor
move your face or head close to the machine during operation.
Before clicking the <CHANGE> button, check to see if there is no one
who is working the internal parts of the machine.
Before clicking the <CHANGE> button, check to see if there is no one
who is near the machine and can be injured when the machine warms
up.
Before clicking the <CHANGE> button, check to see there is no
obstacle (tools and jigs) attached or left in the machine that may
prevent any part inside the machine from operating.
The positions from A to D displayed on the “Nozzle change” window of the dialog box
shown in Figure 10.4.6.1.1 are assigned as shown below when you face the front of
the machine.
A B
C D
“**” displayed as the nozzle number on the “Status” window indicates that the
corresponding nozzle is not assigned on the Setup screen. The leftmost * mark
indicates the position of the ATC to which the nozzle attached on the current head is
assigned.
10 18
10.4.6.2 Signal light control
When you select the [6/Others] command on the menu bar, and then the [2/Signal
light control] command on the displayed menu, the dialog box for controlling the
signal lights appears on the screen as shown in Figure 10.4.6.2.1.
Each command is described on Table 10.4.6.2.1.
Figure 10.4.6.2.1 “Signal light control” dialog box
Table 10.4.6.2.1 Description of each command
No. Command Description
1 Signal light Controls the signal lights (red, yellow and green) (ON/OFF/BLINK), and
controls the signal buzzer (ON/OFF).
2 Status Displays the conditions of the signal lights (red, yellow and green).
Displays the condition of the signal buzzer (ON/OFF).
When you select a command on the dialog box above, the signal light lights up/goes
off/flashes according to the command you selected, or the signal buzzer turns on/off.