8 − 50 ② Count down num. of PW B produced. − Set how to display the number of PW Bs already produced by checking the check box. − W hen you check this check box, t he machine displays the number of PW Bs not produced yet…

100%1 / 419
8 49
8.6 Production Options
When you select the [3/Product] command on the top menu, and then the [2/ Option]
command, or you select the [3/Product] command on the top menu, and then the [1/
PWB Production] command and [4/Option] command in this order, the “Operation
option” screen appears.
Figure 8.6.1 Operation option screen
(1) Setting items
No. Item Description
1 Display num. of PWBs produced in
capital ltr.
Sets how to display the number of PWBs produced.
2 Count down num. of PWB produced. Sets how to display the number of PWBs produced.
3 Integrate num. of PWB produced. Sets how to display the number of PWBs produced.
4 Check release of component after
placing Z up.
Checks if a component is detached from a nozzle when it is
placed on a board.
5 The BOC mark priority recognition is
done.
Sets whether the machine should recognize a BOC mark
prior to a bad mark or not.
(2) How to set
Display num. of PWBs produced in capital ltr.
Set how to display the number of PWBs already produced by checking the
check box.
When you check this check box, the machine displays the number of PWBs
produced during the current production in large characters.
8 50
Count down num. of PWB produced.
Set how to display the number of PWBs already produced by checking the
check box.
When you check this check box, the machine displays the number of PWBs
not produced yet.
When you do not check this check box, the machine displays the number of
PWBs already produced.
Integrate num. of PWB produced.
Set how to display the number of PWBs already produced by checking the
check box.
When you check this check box, the machine adds up the number of PWBs
already produced until you clear the production management information.
(The machine displays the total number of PWBs produced.)
When you do not check this check box, the total number of PWBs produced
is cleared to zero when you press the <Start> key.
Check release of component after placing Z up.
Set whether to check to see if a component is detached from the nozzle
when it is placed on a board by checking the check box.
When you check this check box, the machine uses laser to check to if a
component is not attached on a nozzle when the Z-axis moves up after
component placement. Note that the machine does not perform component
release check for a component centered with the VCS.
When you do not check this check box, the machine ignores the setting of
“Release check” on the Component data screen, and will not check the
existence of a component onto a nozzle.
The BOC mark priority recognition is done.
Set whether to recognize a BOC mark prior to a bad mark.
When you check this check box, the machine recognizes a BOC mark prior
to a bad mark.
9 1
CHAPTER 9 FILE MAINTENANCE
This chapter explains how to manage the production program files stored in the disk.
When you select the [1/File] command on the menu bar, and the [5/File maintenance]
command on the “File” menu, the window shown in Figure 9.1.2 appears
Figure 9.1.1 “File” menu commands
Figure 9.1.2 “File maintenance” menu dialog box