Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第157页
6-47 Board Definition [Block PCB - Same T ype] The CAD infor mation (placement point and part) on the block i s identical. [Block PCB - Diffe re nt T ype] The CAD infor mation (placement point and part) on the block …

6-46
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Clicking the <
Block> button will display the following dialog box with which the PCB
model type is set.
Figure6.12 “Block PCB” dialog box
<1.Use> check box
Selected when performing configuration of the model type and block.
<2. Block Setting> group
<3. Block Type> combo box
Select the type of model configuration. Three types can be selected as follows;

6-47
Board Definition
[Block PCB - Same Type]
The CAD information (placement point and part) on the block is identical.
[Block PCB - Different Type]
The CAD information (placement point and part) on the block is different.
When the Block PCB type is selected in the <Model Type> combo box
Perform setup for the block in the same manner as performing setup for an array PCB.
First, determine the number of blocks to be configured and apply the offset for the
placement origin of the reference block to set the placement origin of the entire block.
<Number X> edit box
Input the number of blocks in the X direction.
<Number Y> edit box
Input the number of blocks in the Y direction.
<Offset X> edit box
Input the offset in the X direction based on the placement origin of the existing
block.
<Offset Y> edit box
Input the offset in the Y direction based on the placement origin of the existing
block.
<Teach...> button
Teach the XY offset based on the placement origin of the existing block..
<Apply> button
Creates the data in the <3.Model Position> group according to the number of X
and Y blocks as well as the X and Y offset.

6-48
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<4. Block Position> group
When Block PCB type is selected in the <Model Type> combo box;
The offset coordinate of the placement origin of each block is indicated. Select <Skip>
column when placement is not performed for the corresponding block.
The procedure to teach the placement origin offset of each block
Select the fiducial camera corresponding to the workstation to which the block
PCB is transferred.
Select the placement origin offset of the block in the <3. Model Position> group.
Click the <Move> button to move to the currently set position.
Click the <Get> button to input the current coordinate.
<Update> button
Saves the PCB model related setup data and closes the “PCB Model” dialog box.
<Cancel> button