4-11 Tools Shortcut M enu <Put all nozzle> button When this Button is clicked on, put s the nozzles in all the heads to the ANC. <V iew All Nozzles / Move Heads S a fe> button Used to move down the Z a xi…

4-10
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Move the object selected in the Combo Box to the position of the assigned
coordinates. At this time, before executing <Move> button, the hole
corresponding to the desired position must be clicked on with a mouse.
<Get> button
Obtain coordinates for XY axis with reference to the object selected in the Combo
Box. At this time, before executing <Get> button, the hole corresponding to the
desired position must be clicked on with a mouse.
<Fiducial Mark Detail…> button
Set the ANC fiducial mark data. For more details. refer to Section “6.3. Fiducial Mark
Setup”.
<Move Next Hole> button
Moves the device selected from the Combo Box in <Teach> group to the hole next to
the currently selected hole in the ANC.
<Shutter Open/Close> button
When this Button is clicked on, the ANC shutter is Opened or Closed.
<Head-Inspect Nozzle Type> button
Clicking this Button will perform the inspection of the type of the nozzle inserted in
the nozzle holder of the currently selected head. Since separate setup is needed to
enable this function, our C/S department must first be contacted.
The nozzles whose types can be checked are as follows:
CN030, CN040, CN065, CN140, CN220
<All-Inspect Nozzle Type> button
Clicking this Button will inspect the types of nozzles inserted in the nozzle holders of
all heads. Since separate setup is needed to enable this function, our C/S department
must first be contacted.
The nozzles whose types can be checked are as follows:
CN030, CN040, CN065, CN140, CN220
<Pick & Put> group
<No real motion> check box
When this Button is checked, manipulates the data for pick and put functions
without actual operation.
<Pick> button
When this Button is clicked on, picks up the nozzle in the currently selected hole
of the ANC. Select the head to pick in the Combo Box in the <Teach> group.
<Put> button
When this Button is clicked on, puts the nozzle in the head selected in the
“Device” to ANC.

4-11
Tools Shortcut Menu
<Put all nozzle> button
When this Button is clicked on, puts the nozzles in all the heads to the ANC.
<View All Nozzles / Move Heads Safe> button
Used to move down the Z axis of all heads of the selected gantry of certain height so as
to check visually if any nozzle exists on the nozzle head.
After the visual check, if clicked again, Z axes of all heads are moved up to the
original position.
<Different ANC Info.In Current PCB file> list box
Shows the difference between the ANC setting of the currently loaded PCB file and
the ANC setting of the currently working equipment system. To change the system
setting to the PCB file setting, click on the <PCB->System> button on the right and
change the nozzles in other holes with different settings to fit the setting.
<PCB->System> button
Change the system setup to the PCB file setup
Warning When Manual ANC movement is executed, the nozzle of
the head and other areas of the machine might collide
unless the programmed nozzle and the actual nozzle
coincide. Be sure to match the programmed nozzle and the
actual nozzle in the machine.
<Close> button
Pressing this Button will save the changed setup and close the current dialog box.

4-12
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
4.4. Operation Mode Change
The accessible MMI menu is different according to the user mode. According to the
purpose of using the MMI, users are classified into Operator, Programmer, Manager and
Service. Please refer to “Chapter 1. Operation Mode and Password Change” for more
information.
4.5. Conveyor
Used to correct the problem occurred during run operation.
Figure4.4 Conveyor System dialog box
4.5.1. PCB In/Out Function
Able to place PCB in the working station in the conveyor or forward it to the next process
of the working station in the conveyor using ‘drag & drop’ with the mouse.
To put a PCB into the machine, select the light green PCB on the left with the mouse and
drag it to the working station to put and drop it (drag and drop). To release a PCB from the
machine, select the PCB in the working station to release and drag and drop it to the light
green PCB on the left (drag and drop).
Board Flow (left Explain for the instance of right side)
The PCB is moved to the working station by ‘drag and drop’ of a PCB in standby
at the left hand side.