14-46 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide 6. The calibr ation is performed automatically . If it is completed, the calibration result is displayed as shown in the following figure. Click the <Up…

14-45
Machine Calibration
Caution Cautions to be taken when inserting the nozzle.
Insert the nozzle by referring to the following figure.
5. The message “Move To Center Position of [Fix1] Camera. To Move, Click [Next]”
appears in the message window. Click the <Next> button to move the head assembly
to the center of the fix-camera.
Direction Setup Pin of CNT20 nozzle
Direction Setup Groove of Nozzle
Holder
The CNT20 nozzle must be inserted
in the nozzle-holder so that the
direction-setup pin of the CNT20
nozzle is suitable for the direction-
setup groove of nozzle-holder.
Otherwise, an error may occur.

14-46
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
6. The calibration is performed automatically. If it is completed, the calibration result is
displayed as shown in the following figure. Click the <Update> button to apply the
new calibration value.

14-47
Machine Calibration
Memo The range of the reference values for the ‘fly-camera calibration’ is as
follows:.
Mega FOV 35
ScaleX:33.1~36.1 (μm/pixel)
ScaleY: 33.1~36.1 (μm/pixel)
R:-1~1(deg)
Mega FOV 45
ScaleX:42.7~45.7 (μm/pixel)
ScaleY: 42.7~45.7 (μm/pixel)
R:-1~1(deg)