Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第211页

7-53 Part Registration When using the rank function, even the s ame part is considered to be a different part depending on the rank. Therefore, considering the LED rank in the T -OLP of the T -Solution, arrange the tape …

100%1 / 566
7-52
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<Rank> group
Clicking the <Rank Setting> button will display the following dialog box that can
set the rank. This function is used only for LED parts.
button
Adds a new rank.
button
Deletes the selected rank.
<OK> button.
Saves the changed rank information and closes the dialog box.
<Cancel> button
Closes the window without saving the changed rank information.
Once the rank is registered, it is possible to select the rank from the “Tape” tab
dialog box as shown in the following figure and check the information on the LED
brightness.
Memo When placing an LED whose rank has been set, check the rank of the
LED supplied from the feeder before starting production.
7-53
Part Registration
When using the rank function, even the same part is considered to be a different
part depending on the rank.
Therefore, considering the LED rank in the T-OLP of the T-Solution, arrange the
tape feeders and perform optimization.
Leaded Part (IC)
Describes the recognition option applied to most of the leaded parts.
<Accuracy Option> Select Box
The user can easily set the detail parameters related to part recognition.
Simple/ Normal/ Detail
It is possible to apply the default set value according to the part recognition
level. If this item is selected, the detail parameter values that can be set by
clicking the <Detail> button will be set according to the items selected from
the <Accuracy Option> selection box.
<Detail> button
Sets the detail parameters related to the recognition of IC parts.
7-54
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<Find Lead Tips Accurately> check button
Selected in cases to used to recognize the lead end accurately. In the case
of the connector whose leads exist at SOP or only one direction with the
number of leads exceeding 8, checking this check button will increase the
recognition accuracy.
<Advance body recognition> check button
Selected in cases to calculates the approximate position of the part by
using the part body information when recognizing the part.
<Use the lead width inspection> check box
Inspects the width of each lead to check if it is within the allowable value.
<Use the lead position inspection> check box
Inspects the length of each lead to check if it is within the allowable value.
<Use Edge Matching> check button
Selected when using the 'Edge Matching' function.
<Threshold for body recognition> edit box
Enabled when the <Use Edge Matching> check button is selected. Set the
Threshold when recognizing the body. (0~100)
If leads exist only in one direction and a pattern similar to the lead exists
on the body when recognizing a connector, inputting 100 for this item can
reduce the dump rate.
<Sampling level for body recognition> edit box
Enabled when the <Use Edge Matching> check button is selected. Set the
sampling accuracy when recognizing the body. (0~10, 0: auto)