Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第490页
16-4 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide AN C Shutter #1(2) Clo s e: C hec k the c losing m ovement of the s hu tter of ANC #1(2). AN C Shut t er #1(2) Open: Check the opening movement of the s…

16-3
Diagnosis
Figure16.4 “SM Tape Feeder base” dialog box
<Cylinder Check> button
Check the state of the cylinder movement. When this button is clicked on, the
following dialog box is displayed.
Figure16.5 “Diagnosis: Cylinder Module Diagnosis” dialog box
<Operation Test> group
Displays the operation list of devices to check.
Place Stopper #1 Up: Checks the up-movement of the stopper #1.
Place Stopper #1 Down: Checks the down-movement of the stopper #1.
BackUp Table #1 Up: Checks the up-movement of the backup table #1.
BackUp Table #1 Down: Checks the down-movement of the backup table
#1(#2).

16-4
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
ANC Shutter #1(2) Close: Check the closing movement of the shutter of ANC
#1(2).
ANC Shutter #1(2) Open: Check the opening movement of the shutter of
ANC #1(2).
<Automatic> button
Checks devices in the <Operation Test> group in order automatically.
BUT Speed Test
Test the Up/Down speed of the backup table.
BUT Up Delay: Indicates the upward movement speed of the backup table.
BUT Down Delay: Indicates the downward movement speed of the backup
table.
Up/Down Count: Sets the Up/Down movement test count.
<BUT Run>: Tests the Up/Down speed of the backup table.
<Close> button
Closes the dialog box.

16-5
Diagnosis
16.2. Conveyor [F3]
Checks the status of various devices in the conveyor group. When this submenu is selected
on, the following dialog box is displayed. Please refer to“4.5 Conveyor ” for more
information.