Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第435页

14-83 Machine Calibration 4. Input the value, which was obtained by adding the value inputted in the < S topper X> edit box of Stati on 2 to the value measure in the previous stage, in t he <Stopper X> edit b…

100%1 / 566
14-82
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
2. Select <Stopper X> edit box of Station 2 with the mouse pointer and click the <Move>
button to move the corresponding fiducial camera to the Stopper X position of Station
2.
3. Check the scale of the steel ruler matching the crosshair center of the fiducial camera
and memorize this measurement value.
14-83
Machine Calibration
4. Input the value, which was obtained by adding the value inputted in the <Stopper X>
edit box of Station 2 to the value measure in the previous stage, in the <Stopper X>
edit box of Station 3. For example, if the coordinate of Stopper X of Station 2 is
628.226 mm and the value measured by the steel ruler is 750.7 mm, input 1378.926
mm in the <Stopper X> edit box of Station 3 and 1346.426mm in the <Sensor X> edit
box, which was obtained by subtracting 32.5mm from the value inputted in the
<Stopper X> edit box.
5. Save the data by clicking the <Update> button.