Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第62页
2-4 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide Help Provides the help in HTML fo rm a t for the application program o f this equipment. 2.1.2.2. Main Toolbar 2.1.2.2.1. The submenu tool-bars of the PCB …

2-3
Structure of MMI Menu
ANC
Registers various information on the ANC (Auto Nozzle Changer).
Operation mode
Changes the operation mode.
Conveyor
Executes the conveyor dialog box.
Position
Used when it is necessary to refer to the current coordinate of each driving axis during
teaching or calibration.
Manual Tool
Used when it is necessary to refer to the current coordinate of each driving axis during
teaching or calibration.
Dump Info.
Used to check the message window indicating the information on the parts and feeders
dumped due to placement error.
Dump all
Used to dump all parts picked up by the head to the dump box.
Docking Cart
Used to manipulate the movement of the docking cart clamp in the machine to which
the docking cart is applied.
PM Manager
The PM Manager is a management menu that is used for the maintenance of the
machine in the MMI (Man-Machine Interface), an application program for machine
operation. The items to be inspected as well as check periods can be checked through
the PM Manager, and the machine can be managed more efficiently through the
schedule check function. For more details, refer to the “Appendix. PM Manager’s
Guide” of “Administrator’s Guide”.
Data Logging
Used to find the cause of problems occurring in the machine.
2.1.2.1.3. The submenus of the help menu
Language
Enables indication of the messages in English while operating the equipment.
About
Displays the equipment’s application program’s current version and miscellaneous
information.

2-4
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Help
Provides the help in HTML format for the application program of this equipment.
2.1.2.2. Main Toolbar
2.1.2.2.1. The submenu tool-bars of the PCB Edit menu tool-bar
Board
Register various information on the board to be produced..
Part
Register various information about the components to be placed.
Feeder
Sets the data related to the Tape, Stick, and Tray Feeder.
Step
Defines the step for placement operation.
ANC Cfg
Displays the nozzle information in case the ANC setting of the current PCB file is
different from that of the current system.
Cycle
Checks the cycle by step.
Opti
Executes Optimizer..
Cancel
Closes the dialog box for the Board, Part, Feeder, and Step.
Layout
Indicates the shape of PCB and placement position of the parts.
2.1.2.2.2. The submenu tool-bars of the production menu tool-bar
Start
Starts operation after downloading PCB.
Stop
Stops operation.
Cont.
Continues previous operation..
Finish
Finishes the downloaded operation completely.

2-5
Structure of MMI Menu
T/ F Cnt
Sets the position of the pocket to start picking up components from the Tray Feeder.
PCB D/L
Transmits PCB operation data to the equipment. It is possible only when the
equipment status is ‘Finish’.
Pd. Info
Checks the number of pickups, placements, and pickup error rates by head, nozzle,
and feeder.
Flux
Perform setup for the warning message related to the operation of the flux module.
2.1.2.2.3. The submenu tool-bars of the Utility menu tool-bar
Print
Used to print a PCB file or system data.
Pd. Info
Reports various production management data for the equipment (PCB information,
and Log information).
Copy ..
Use it to copy the existing PCB file data to other PCB files.
File Man
Use it to copy, delete, rename and clear the files related to MMI.
By Pass
Use it to bypass a PCB on the conveyor without placement operation.
Warmup
Warms up the driving axis after power supply.
2.1.2.2.4. The submenu tool-bars of the Diagnosis menu tool-bar
I/O
Check the I/O status.
Conveyor
Checks the Stopper, Backup Table, Hole/Edge Fixture, and Conveyor Flow.
Light
Checks the Camera Light.
Vacuum
Checks the Vacuum of each head