Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第350页
13-20 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide <OK> button T ransmits the set data to the equipment a n d closes the dialog box. <Cancel> button Ignores the set data and closes the dialo…

13-19
Production Setup
<Grid> group
Set the position of the pocket to start.
<Step> column
Displays the number of tray step.
<X> column
Set the X position of the pocket.
<Y> column
Set the Y position of the pocket.
<Remain> column
Indicates the number of parts remaining in the corresponding pallet.
<Reset> column
After refilling components for empty pallets, Clicking this button initializes the
pocket position to start (X=1, Y=1) on each pallet.
<Part> column
Displays the name of the component supplied the Tray
<All Reset> button
Initializes the pickup point for upper pallets to the first pocket (X = 1, Y = 1).
<Refill All> button
Clicking this button after resupplying those lower pallets which have run out of parts
will initialize the pickup position to the first pocket (X = 1, Y = 1) for each pallet.

13-20
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<OK> button
Transmits the set data to the equipment and closes the dialog box.
<Cancel> button
Ignores the set data and closes the dialog box.
13.7. PCB D/L [F7]
Transmits the PCB data set in the <PCB Edit> menu to the equipment. Transmission is
possible only when the equipment status is “Finish”.
13.8. Pd. Info [F8]
Displays placement operation data for head, nozzle and feeder. Please refer to “18.1
Production Information Management [Pd. Info]” for more information.
13.9. Flux. [F9]
Perform setup for the warning message related to the operation of the flux module.
<Squeeze Warning Alarm>
Clicking the <Reset> button will initialize the set flux module cleaning cycle. The
setup of the corresponding item can be performed in the ‘Flux’ tab dialog box in the
‘Periph.’ submenu of the ‘Sys.Setup’ menu.

Calibration & Setup