Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第521页

18-5 Producti o n Information Management  <PPM<->%> button Converts the in dicated unit. (PPM<->%)  <Close> button Closes the screen.

100%1 / 566
18-4
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<- Place Time>
Indicates the time of installation from turning on the power of the equipment
to the present time.
<- Transfer Time>
Indicates the total time of PCB transportation from turning on the power of the
equipment to the present time.
<- Entry Wait>
Indicates the total time the PCB waits until the current time for placement
after the machine is turned on.
<- Exit Wait>
Indicates the total time that the PCBs have been worked completely waits
until the current time for transfer to the next machine after the machine is
turned on.
<Stop Time> group
Indicates the time equipment was in stop status from turning on the power of the
equipment to the present.
<Run Stop Count>
Indicates the machine stop count during automatic production.
<Stop>
Indicates the machine stop count performed by the user during automatic
production.
<Error Stop>
Indicates the count of machine stop performed by an error during automatic
production.
<Reset> button
Initializes all the indication information.
<Print To File> button
Saves the placement information related with PCB production in the assigned folder
(C:\ SmartSM\Pdinfo) in text file(*.txt) format.
18-5
Production Information Management
<PPM<->%> button
Converts the indicated unit. (PPM<->%)
<Close> button
Closes the screen.
18-6
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
18.1.2. Head
Displays the operation data for each head. Shows the overall statistics information related
with placement.
<Head> column
Displays the total head number.
<Pickup> column
Displays the total number of components picked up.
<Place> column
Displays the total number of components placed.
<Error> column
Indicates the number of part placement failures after recognizing the picked up parts
using ‘Vision’.
<Error (PPM)> column
Recognize the picked part by using the vision system and indicate the non-placement
error in PPM unit.
<Pick Miss> column
Indicates the number of part pickup failures.
<Part NG> column
Indicates the number of part recognition failures using ‘Vision’ after pickup of parts.
<Dump> column
Indicates the number of times part dumping has been performed by the corresponding
head.