Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第221页
7-63 Part Registration <Feeding Y Offset> edit box Used when supplying parts by setting the pitch of the 8mm tape feeder to 4mm. If the size Y of the part is greater than 2 . 2mm, the part pickup may interf e re …

7-62
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
7.2.2.7. COMMON DATA
Sets the handling parameters related to part pickup and placement.
1: Common Parameter
<Package> tab
Sets the parameters related to part supply and pickup.

7-63
Part Registration
<Feeding Y Offset> edit box
Used when supplying parts by setting the pitch of the 8mm tape feeder to 4mm.
If the size Y of the part is greater than 2.2mm, the part pickup may interfere with
the tape guide.
In this case, it is possible to set the part pickup position by inputting the Y offset
value in the <Y Offset> edit box. (Input range: 0 ~ 0.5mm)
<Use the Splicing Skip> check button
The splicing skip function is to supply parts by skipping some parts in the section
where existing tape is spliced with a new tape in the tape feeder since parts are not
supplied at this connected section.
When using this function, select this check box.
<Splicing Skip Count> edit box
If the splicing check sensor detects a spliced section, parts are supplied by
skipping as many parts as is set here.
<Splicing Skip Margin> edit box
Inputs the number of parts to be skipped in addition to the part count set in the
<Splicing Skip Count> edit box.
<Feeding Speed> selection box
Selects the feeding speed of the tape feeder selected from the <Feeder> selection
box.
In the case of a micro part, it may jump up and cause a pickup error during part
feeding. This problem may be solved by reducing the part feeding speed.
Normal: Supplies parts at normal speed.
Slow1: Supplies parts at a slightly slower speed.
Slow2: Supplies parts at slow speed.
<Part Count/Reel> edit box
Input the default number of parts for the part reel that supplies the corresponding
part. When using the Basic IT function, it is used as default count for the
corresponding part.
<Reel Transparency> check box
When splicing the tape using transparent tape, this function is selected in the case

7-64
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
that the vision system can detect the tape splicing.
<Pickup Data> tab
Sets the parameters related to the pickup of the supplied parts.
<Sync Pickup Tol(%) - X/Y> edit box
When more than two spindles pick parts from the feeder simultaneously, sets the
tolerance for the pick-up position in the X/ Y direction as a percentage of the part
size in the X/ Y direction.
The default value is 15%. If the tolerance for simultaneous pickup is greater than
the default value, simultaneous pickup is performed well, but may cause a pickup
error.
In the case of micro parts, this value must be small, and pocket teaching must be
performed for parts smaller than the 1005 chip to reduce the part dump rate.