Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第415页

14-63 Machine Calibration 11 . The measurement result can be confirmed in the Head Of f set dial og box.

100%1 / 566
14-62
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
8. Then the message “Next, Remove the Calibration Nozzle From Head 1. Click [Next]
for Moving Down Head. After Moving, Remove the Nozzle Manually” appears. Click
the <Next> button to remove the calibration tool from the nozzle-holder of Head #1
manually.
9. Form Head #2 to Head #10, perform calibration in the same manner as it was
performed for Head #1.
10. If the calibration procedure is completed for all heads normally, the result is displayed
as shown in the following figure. Click the <Update> button to apply the calibration
value.
14-63
Machine Calibration
11. The measurement result can be confirmed in the Head Offset dialog box.
14-64
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Memo The range of the reference value for the ‘Head Offset Calibration’ are
as follows:
Head 1
X:-0.06mm~0.06mm, Y: -0.05mm~0.05mm
Head 2
X:14.94mm~15.06mm, Y: -0.05mm~0.05mm
Head 3
X:29.94mm~30.06mm, Y: -0.05mm~0.05mm
Head 4
X:44.94mm~45.06mm, Y: -0.05mm~0.05mm
Head 5
X:59.94mm~60.06mm, Y: -0.05mm~0.05mm
Head 6
X:74.94mm~75.06mm, Y: -0.05mm~0.05mm
Head 7
X:89.94mm~90.06mm, Y: -0.05mm~0.05mm
Head 8
X:104.94mm~105.06mm, Y: -0.05mm~0.05mm
Head 9
X:119.94mm~120.06mm, Y: -0.05mm~0.05mm
Head 10
X:134.94mm~135.06mm, Y: -0.05mm~0.05mm