Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第456页

15-20 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide Figure15.11 Wh en the Fid Camer a is selected Figure15.12 Wh en the Fix C amera is selected  <1. T est Ar ea> group Designates the area for which th…

100%1 / 566
15-19
System Setup
For the Fly Camera
Input the side illumination value within the range of 256 values.
For the Fix Camera
Input the side illumination value within the range of 4096 values.
<Back1> / <Back2> column
Enabled only when the fix camera was selected. The value within the range up to
4096 for each light level is inputted.
<Mapping/Test> button
Perform test or automatic mapping for the light level for the camera selected from the
<Select Camera> group.
Figure15.10 When the Fly Camera is selected
15-20
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Figure15.11 When the Fid Camera is selected
Figure15.12 When the Fix Camera is selected
<1. Test Area> group
Designates the area for which the nozzle for test checks the brightness of the
lighting. The are can be designated up to 4. the search area and excluded area are
designated together. The test area is set automatically. Do not change this value.
15-21
System Setup
Figure15.13 Bottom Shape of Calibration Nozzle for Fly Camera
Figure15.14 Bottom shape of the calibration plate for the Fid camera
Figure15.15 Bottom shape of the calibration nozzle for the Fix camera
<2. Camera> group
Selects the camera for performing lighting brightness test or mapping. Activated
cameras can be designated at the same time.
<3. Tool Setting> group
Performs test or preparation for mapping.
<Prepare Test /Mapping> button
Return all nozzles mounted on the head to each corresponding ANC hole.
Before doing so, arrange the LightFly nozzle, a nozzle for calibration into the
No. 1 hole of the ANC.
If the nozzle arrangement is finished, the <Start> button and <Test> button in
the <<<Mapping>>> group.
<4. Search Area> group
Clicking the button corresponding to the light for which mapping is to be
performed will display the following dialog box.