8-4 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide Figure8.4The screen in which the <Rank> column is selected from the “Feeders” dialog box Double clicking the <Rank> combo b ox after selecting th…

8-3
Feeder Setup
Figure8.3“Feeder: When various devices are installed in the Feeder Base” screen
Of the items displayed in the <Type> column, explanation is given on the
following.
1Half: The corresponding slot is occupied by 1 device installed in the adjacent
slot.
2Half: The corresponding slot is occupied by 2 devices installed in the adjacent
slot.
Full: The corresponding slot is entirely occupied by the device installed in the
adjacent slot.
<Rank> column
Used to register and manage the rank for LED parts. When enabling the <Rank>
column, select the ‘General’ tab dialog box from the ‘Pref.’ submenu of the
‘Sys.Setup’ menu and select the <Use Rank Check> check box.
If an LED part is not registered in the part registration dialog box, the
corresponding part does not appear in the <Rank> column.
The following is the screen where the feeder supplying LED parts is selected from
the feeder base and the rank is selected from the <Rank> column.

8-4
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Figure8.4The screen in which the <Rank> column is selected from the “Feeders” dialog
box
Double clicking the <Rank> combo box after selecting the LED part will execute
the dialog box that manages the rank as shown below.
Figure8.5“Rank” dialog box
<Push> column
When the tape feeder is installed in the corresponding slot, Select the number of
cylinder movements needed to move the part tape forward by 1 pitch.
<X> column
When the tape feeder is installed in the corresponding slot, set the X position to
pick up the component supplied from the tape feeder.
<Y> column
When the tape feeder is installed in the corresponding slot, set the Y position to
pick up the component supplied from the tape feeder.

8-5
Feeder Setup
<Z> column
When the tape feeder is installed in the corresponding slot, set the Y position to
pick up the component supplied from the tape feeder.
<R> column
When the tape feeder is installed in the corresponding slot, set the R
position(rotation angle of the head) to pick up the component supplied from the
tape feeder.
Before picking up the part, the head is rotated as much as is set up for part pickup.
For example, when the special rectangular nozzle is used to pick up the connector,
the part can be picked up without problem only when the longitudinal direction of
the nozzle matches with the longitudinal direction of the part.
However, if the nozzle is set up so that the longitudinal section of the nozzle
becomes long and the horizontal section of the part becomes long, the nozzle must
of course be rotated by 90 degrees to pick up the part normally before picking up
the nozzle.
In this case, it is used to set up the rotation angle when picking up the part.
<PartR> column
When the tape feeder is installed in the corresponding slot, set the ing angle for the
component supplied from the tape feeder.
Memo Definition on component supply angle and pick-up angle
Supply angle (In the case of user):
Supply angle (In the case of user):
<Skip> column
When the tape feeder is installed in the corresponding slot, select whether to pick
up the component supplied from the tape feeder or not.
To pick it up leave the check box as it is, and check the check box not to pick it up.